Type
LE 5000 DF
HT
LE 10 000 DF
HT
Voltage V~
3
×
230
3
×
400
3
×
200 3
×
400
3
×
400
3
×
480 3
×
400 3
×
480
Frequency Hz
50 / 60
50 / 60
50 / 60
Power consumption kW
8
4.5 6.5 7.5 8
7
7.5
11
5.5 11 17 8 16
15
Max. air outlet temperature °C
700
900
650
900
Max. air inlet temperature °C
150
150
150
150
Min. air volume (20°C) l/min.
560 320 460 530 560 380 400 580 420 840 1300 610 1220
800
Max. static pressure. bar
1
1
Emission level
LpA (dB)
< 70
< 70
Weight kg
1.9
3.1
3.1
3.4
4.0
Size mm
page 3
page 4
Mark of conformity
Approval mark
Protection class I