10
Application
The Leister LE 5000 DF, LE 5000 DF HT, LE 10 000 DF and LE 10 000 DF HT air heaters are suitable for
building into machines, installations or appliances and are designed for continuous operation.
Their most important applications include; drying and heating, thawing, accelerating and removal,
sterilising, smoothing, polishing, activation and dissolving, separating and fusing, shrinking, removal.
Please read operating instructions carefully before use
and keep for future reference.
Operating Instructions
GB
Danger of death
when opening the device, as live parts and connections are
exposed. The device must be fully disconnected from the mains before opening it.
Danger of fire and explosion
if air heaters are installed and used incorrectly,
especially in the vicinity of flammable materials and explosive gases.
Warning
Danger – can cause burns!
Do not touch the heating element tube and nozzle
while they are hot. Allow the device to cool. Do not direct hot-air jet towards
people or animals.
The
nominal voltage
indicated on the device must correspond to the mains vol-
tage.
Keep away from wet and damp areas.
The device must
not be left unattended
when in use.
Heat can reach combustible materials which are out of sight. The device may only
be used by
trained personnel
or under their supervision. Children may not use
the device under any circumstances.
100
480
Caution
Devices of protection class I
must be earthed with a protective earth conductor.
Air heaters
LE 5000 DF; LE 10 000 DF; LE 5000 DF HT, LE 10 000 DF HT