3.1
Entering Grade
Direct Grade Entry
Grade Entry by
Digit
Grade Zero
The grade in either axis can quickly be set to zero by pressing both the
Up and Down buttons simultaneously while in either grade entry mode.
When changing grade using the direct entry method, the counter will
always stop at zero. Release the button and press again to continue
counting beyond zero.
Grade Capability
The Rugby 320 SG can have up to 25.000% grade in the X-axis.
The Y-axis does not have grade capabilitiy, and is a “level only” axis.
)
If no button is pressed, the display will revert to the main display after
ten seconds.
Press
POWER
to turn the Rugby on.
Press
X
to enter X-axis grade mode.
Use the
UP
or
DOWN
buttons to set the desired grade.
Press
X
to exit.
While in the grade entry screens, press the
STAR
button and a
cursor will appear on the +/- sign.
Press the
STAR
button to move the cursor to the right.
Press the
UP
or
DOWN
buttons to change the sign or the digit
that is highlighted.
Press
X
to exit.