3.
Turn on the instrument, and, if tilt correction is set to
On
, the laser
plummet will be activated automatically, and the level screen
appears.
☞
The bubble of the electronic level and the arrows for the
rotating direction of the footscrews only appear if the
instrument tilt is inside a certain levelling range.
4.
Centre the electronic level of the first axis by turning the two
footscrews. Arrows show the direction of rotation required. The first
axis is levelled, when the bubble is exactly between the squared
brackets [] of the single axis bubble tube.
☞
When levelled correctly, checkmarks are displayed.
5.
Centre the electronic level for the second axis by turning the last
footscrew. An arrow shows the direction of rotation required.
When all three bubbles are centred, the instrument has been per-
fectly levelled up.
6.
Accept the setting.
18424_001
Under some circumstances the laser
dot is not visible, for example over
pipes. In this case, using a transpar-
ent plate enables the laser dot to
be seen and then easily aligned to
the centre of the pipe.
Position over pipes or
holes
32