Rugby 610, Accuracy Adjustment
30
7
Accuracy Adjustment
About
• It is the responsibility of the user to follow operating instructions and to periodi-
cally check the accuracy of the laser and work as it progresses.
• The Rugby is adjusted to the defined accuracy specification at the factory. It is
recommended to check the laser for accuracy upon receipt and periodically there-
after to ensure accuracy is maintained. If the laser requires adjustment, contact
your nearest authorised service centre or adjust the laser using the procedures
described in this chapter.
• Only enter the accuracy adjustment mode when you plan to change the accuracy.
Accuracy adjustments should only be performed by a qualified individual that
understands basic adjustment principles.
• It is recommended to perform this procedure with two people on a relatively flat
surface.
7.1
Checking the Level Accuracy
Checking the level
accuracy step-by-
step
Step
Description
1.
Place the Rugby on a flat, level surface or tripod approximately 30 m (100 ft)
from a wall.
2.
Align the first axis so that it is square to a wall. Allow the Rugby to self-level
completely (approximately 1 minute after the Rugby begins to rotate).
3.
Mark the position of the beam.
4.
Rotate the laser 180° and allow it to self-level.
5.
Mark the opposite side of the first axis.
6.
Align the second axis of the Rugby by rotating it 90° so that this axis is
square to the wall. Allow the Rugby to self-level completely.
005772_001
30 m (100 ft)
30 m (100 ft)
X+
X—
005773_001
30 m (100 ft)
30 m (100 ft)
Y+
Y—