Page 158
Data entry/Programming
Group 7
Release R1.12 en
JET2 neo
With the two buttons
<Mix only ink >
(1) and
<Mix only solvent >
(2) only ink or solvent
can be supplied to the hydraulic circuit.
These functions allow to set the viscosity of the ink fast to a lower or higher value.
The execution of addition of the selected medium is displayed by an accordant message
(3 or 4).
With the button
<Stop>
(5) the particular process will be finished.
Attention!
By the addition of solvent or ink the ink can be diluted or concentrated
too much! Therefore this function should be only carried out by qualified
personnel.
6. Fill up routine:
The fill up routine must be carried out the first time the device is started up.
Further information about how to carry out the fill up routine can be
found in the
chapter Cary out fill up routine
(page 40)!
7. Ignore all error messages and alarm messages:
With this function the error- and alarm messages of the device e.g. for starting up, filling,
or for service works can be canceled.
By pressing the button
<Ignore error messages- and warnings>
the function is turned
on or off.
8. Drain routine:
The drain routine consists of the individual functions
<Deplete ink>
and
<Deplete
solvent>
. The functions serve to drain the two storage tanks and
must
be carried out
when shutting down the device.
For further information please contact the Leibinger-Service Department
or your authorized dealer!
Summary of Contents for JET2 neo
Page 1: ...Manual LEIBINGER JET2NEO Release 1 12en ...
Page 2: ......
Page 11: ...Group 1 Table of contents Page 9 JET2 neo Release R1 12 en ...
Page 12: ......
Page 21: ...Group 2 Safety Page 19 JET2 neo Release R1 12 en 2 4 Safety sticker Figure 1 Safety sticker ...
Page 276: ...Page 274 Appendix Group 12 Release R1 12 en JET2 neo Interface X4 Inputs Interface X3 Outputs ...