Operating instructions
Operating the SuperVario® X
14
3.3 Switching on / off
Danger!
The drive motor starts immediately when switched on.
Make sure that no-one is in the danger area when you
switch the system on.
Press the button.
The speed of the spreading disc and
the slide opening is displayed. The
slide is always closed when switching
on the drive motor.
> Speed
200
Slide
29
If this message is displayed, a cable is damaged
or a plug disconnected.
> Speed
200
Spr. connection
Low temperatures can cause the empty indicator to respond slowly.
Check the setting:
1. Let the spreader run for approx. one minute with the slide closed.
2. If the slide is now opened, the empty indicator must respond after
approx. five seconds.
3. If this does not happen, place the empty indicator in the negative range
by 5%, see chapter
“4.6 Adjusting the empty indicator” on page 22
.
Autostart
If the motor is difficult to start due to heavy loads, the motor starts up to
10 times in alternating directions. If the agitator cannot break free as a result,
the motor is automatically switched off. The following message is shown in
the display:
Disc blockage
.
Danger!
Never open the hopper or touch the spreading disc when
the drive motor is running.
Switch off the drive motor and make sure that the motor
is stopped before opening the hopper or touching the
spreading disc.