OMEGA
Installation Manual
Edition July 2013
Omega
platform lift
page 21 of 46
Step 8. Programming the unit
The menu can be used for parameterization,
maintenance and fault finding. There are 2 forms of
the menu, the extended and the standard menu. The
extended menu is used for programming and
adjustments during installation. The standard menu is
for use during general operation of the unit and
allows minor parameter adjustment and fault finding.
The switch S1 on the platform control board activates
the standard or the extended menu.
Position Standard Menu
Position Extended Menu
Menu item
Std.
menu
Ext.
Menu
Description
Language
X
X
Menu language can be selected
Errors
X
X
The last 20 errors that occurred can be read and the
lift of errors can be deleted.
Acknowledge
errors
X
This function allows acknowledging an error and thus
setting the unit into function again. Depending on the
type of error this function can only be performed in the
landing stations or as well on the driveway.
Operation time
X
X
The operating hours of the unit can be read and reset.
Alert output
X
Allows adjustment of the used alert outputs and their
frequency.
Radio version
X
Allows the selection of the used radio control version.
Motor config.
X
Allows the adjustment of the motor control parameters
including the different drive speed frequencies.
Options
X
Allows to programme special functions of the lift
Teach-in start
X
This start the teach modus for the different drive
speed. This can only be started in the lower landing
station.