Pull back the tension rope inside the upper tube so that it stops where you want to put
the platform onto the rail. The fixing bracket must be a minimum of 810mm above
ground floor level.
Add the current collector into the upper tube next to the fixing bracket. Make sure the
spring between the current collector and the upper fixing bracket is securely attached
to the current collector. This spring is responsible to make the electrical contact
between the tension cable and the platform control board.
Fix spring with
screwdriver on pin
Sliding contacts
connect rail with
control board
(electrical mass)
Pull
back
Hole in upper fixing bracket should be located
minimum 810mm above lower floor level