IMPORTANT:
Only install the locking system when it is unlocked. Hand-tighten all screws. The use of the ejector
pin in connection with spring-loaded hinges must be checked on a project-specific basis.
GENERAL ASSEMBLY INSTRUCTIONS
Maximum door thickness for non-metallic doors: 19 mm
The maximum door thickness for non-metallic doors depends, among other things, on the reading range between
the lock and the transponder. The reading range can vary depending on the transponder. A compatibility and reading
distance test is necessary when using existing third-party transponders.
Installation for locker walls with doors hinged on the right and left
The lock has two LEDs aligned symmetrically on the front of the lock. Only one lightpoint per lock is recommended in
the door. Due to the symmetrical arrangement of the lock, locks and lightpoints can always be installed at the same
height on a locker wall regardless of left- and right-handed doors.
MOUNTING ON NON-METAL SURFACES
The lock is mounted on the right or left wall inside of the locker, depending on the door hinge. The locking pin is
mounted on the inside of the door.
The following describes the individual steps for installing the lock on the inside of the cabinet for a locker with a
right-handed door.
• Pre-drill the four mounting holes for the lock as shown in the drawing (see figure: Mounting position on
non-metallic surfaces). No through hole!
• Insert the plug of the connecting cable that connects the lock and controller into the socket on the lock until it
clicks. Place the connecting cable in loops that are large enough in the lock housing to enable later assembly
/ disassembly (see figure: inserting the connecting cable into the lock). The cable must be routed out of the
locker so that it can be plugged into the controller later on (see operating instructions “Primary Controller /
Secondary Controller”). If the cable is laid in the inside of the locker, the plastic edge for the cable breakth-
rough must be broken out on the back of the lock.
• Please note on page 12 the recommendations and options for laying cables between the lock and controller
and the additional drilling that may be necessary. In the following drawings, a hole in the body side wall is
shown as an example.
The distance between Captos or Captos iCharge locks must be at least 5 cm.