![Lehle DUAL EXPRESSION Operating Instructions Manual Download Page 25](http://html.mh-extra.com/html/lehle/dual-expression/dual-expression_operating-instructions-manual_1872283025.webp)
25
LEHLE GmbH · Germany · www.lehle.com · [email protected]
USER FLOW MAP
CALIBRATION OF THE PEDAL RANGE AND SWITCH OUTPUT
Entering the calibration process menu
Release the 10K soft touch button
Press and hold the 10K soft
touch button and reconnect
the power supply connector
The blue 10K switch LED and
the white 50K TRS LED are
flashing alternately
Calibrating the relay switch output
Calibrating the pedal range
Press the 50K soft touch button
50K TRS LED flashes
Blue switch LED flashes
Move the rocker within 3 sec-
onds to the position you want
the relay to be triggered
Blue switch LED stops flashing
Move the rocker within 5 sec-
onds to the most minimal heel
position and then into the maxi-
mum toe position
50K TRS LED stops flashing
Pedal reboots
Pedal reboots
Press the 10K soft touch button