![Lehle DUAL EXPRESSION Operating Instructions Manual Download Page 14](http://html.mh-extra.com/html/lehle/dual-expression/dual-expression_operating-instructions-manual_1872283014.webp)
LEHLE GmbH · Germany · www.lehle.com · [email protected]
14
In factory setting the pedal range of the
LEHLE DUAL EXPRESSION is perfectly
calibrated and the switch output of the
10K socket is being triggered in the last
few millimetres.
Normally, it doesn’t need a calibration
again. Nevertheless, you can adjust the
pedal to your own requirements.
1.) Entering the calibration process menu
To enter the calibration process menu,
first disconnect the power supply connec-
tion.
Press and hold the 10K soft touch button
and reconnect the power supply connec-
tor. You can now release the soft touch
button.
The blue 10K switch LED and the white
50K TRS LED are flashing alternately.
2. Calibrating the pedal range
In order to calibrate the pedal range,
where the minimum (heel) and the maxi-
mum (toe) position of the pedal range
should be reached, in the calibration pro-
cess menu (1.) the 50K soft touch button
needs to be pressed.
The 50K TRS LED flashes.
Move the rocker within 5 seconds (say
“Lehle switcher” five times) to the most
minimal heel position and then into the
maximum toe position.
The pedal learns these two positions
and stores the values inside. After the 5
seconds the 50K TRS LED stops flashing,
goes off and the calibration process is
finished.
The LEHLE DUAL EXPRESSION reboots
again.
How long the pedal range shall be, is
your decision.
This can be all the way to the stop or
shortly before, if you like a decreased
pedal range.
As in the factory setting, we recommend
the use of the whole pedal range, since
minimum and maximum values can often
be set at the effects pedal itself.
CALIBRATION OF THE PEDAL RANGE AND SWITCH OUTPUT
!
On page 25 you will find a user flow
map, where all these procedures are
shown.