DESCRIPTION AND OPERATION

The RS-250-N Universal Application Wall Switch Vacancy Sensor is designed to 
replace a standard light or fan switch. It is ideal for living and dining rooms, family 
rooms, bedrooms, bathrooms and any other indoor area in a residential space 
where occupancy sensor-based manual ON/OFF controls are desirable. 

Like a standard switch, you press the ON/OFF button to turn the light or 
fan (controlled load) ON and OFF. Unlike a standard switch, the RS-250-N 
automatically turns OFF the controlled load after the coverage area has been 
vacant for a period of time (Time Delay). If motion is detected within 30 seconds 
after it automatically turns OFF, the RS-250-N automatically turns the load back 
ON.

While the sensor is factory preset as a Vacancy Sensor with manual ON operation, 
it can be adjusted to work as an Occupancy Sensor that turns the controlled load 
ON automatically upon detection of occupancy in the area.

Night Light

While the controlled load is OFF, the nightlight built into the RS-250-N is ON. 
When the load is ON, the nightlight is OFF.

Operating Modes

There are two operating modes to select from during set up:

MODE 1

 

Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press 

the ON/OFF button to turn the load ON. The RS-250-N keeps the load ON until no 
motion is detected for the selected time delay period (adjustable from 15 seconds 
to 30 minutes). There is a 30 second reset delay. If motion is detected during this 
time, the sensor turns the load back on automatically. After the reset delay time 
has elapsed, the ON/OFF button must be pressed to turn ON the load.

MODE 2

 

Occupancy sensor (Auto-ON/OFF with manual control and reset to 

auto after 5 minutes of vacancy): The load turns ON and OFF automatically based 
on occupancy detection. The RS-250-N keeps the load ON until no motion is 
detected for the selected time delay period. If the load is turned OFF manually, 
automatic-ON is re-enabled when no motion is detected for 5 minutes. This 
prevents the load from being turned ON after it was deliberately turned OFF.

RS-250-N

Universal Application Wall Switch

 Vacancy Sensor

with Manual ON/OFF  

and Nightlight  

Lens

ON/OFF button 

SPECIFICATIONS

Voltage ............................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
 

Incandescent or fl uorescent ............................ 0-600 Watts

 

Fan motor ..................................................................  1/6 hp

Time Delay Adjustment .................... 15 seconds to 30 minutes
Light Level Adjustment ....................................... 10 fc to 150 fc
Environment ..................................Residential Indoor use only
 

Operating Temperature ............... 32° to 131°F (0° to 55°C)

 

Humidity ...................................... 95% RH, non-condensing

Tools Needed
 Insulated 

Screwdriver

 Wire 

Strippers

Santa Clara, CA 95050

Call 888.817.0571 for Technical Support

Nightlight

Summary of Contents for WattStopper RS-250-N

Page 1: ...r Manual ON OFF Auto OFF The user must press the ON OFF button to turn the load ON The RS 250 N keeps the load ON until no motion is detected for the selected time delay period adjustable from 15 seco...

Page 2: ...e the switch box After the power is turned OFF at the circuit breaker box remove the existing wall plate and mounting screws Pull the old switch out from the wall box 2 Identify the type of circuit In...

Page 3: ...button Slide the button downward approximately 1 2 inch to expose the mode button and adjustment trimpots Setting up the Operating Mode Select the operating mode by pressing the Mode button The night...

Page 4: ...led load turns OFF after 5 seconds if no motion is detected 3 Move into the coverage area The controlled load turns ON for 5 seconds each time the sensor detects motion After 5 seconds expire without...

Page 5: ...on the part of Watt Stopper Legrand for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property rev...

Page 6: ...encuentra encendida Cuando por el contrario la carga controlada se encuentra encendida la Luz Nocturna se encuentra apagada Modos de Operaci n Es posible elegir entre dos modos de operaci n durante l...

Page 7: ...e exista detecci n INSTALACION Y CABLEADO ADVERTENCIA Desconecte la corriente que alimenta la caja de conexiones apagando el disyuntor breaker o removiendo el fusible para el circuito correspondiente...

Page 8: ...ENCENDIDO APAGADO por ambos extremos y desl celo hacia abajo aproximadamente 1 2 pulgada de tal forma que el Bot n de Selecci n de Modos y las Perillas de Ajuste queden expuestas Selecci n del Modo de...

Page 9: ...n de ocupaci n si la cantidad de luz natural es mayor a la existente actualmente 6 Reajuste el tiempo de retardo de apagado al valor deseado Advertencia No sobregire la perilla de ajuste del Nivel de...

Page 10: ...apaga autom ticamente Presione el bot n de ENCENDIDO APAGADO Si la carga se apaga prosiga con el siguiente paso El tiempo del retardo de apagado puede ser con gurado desde 30 segundos hasta 30 minutos...

Reviews: