LEGRAND WattStopper DW-100 Installation Instructions Manual Download Page 8

ORDERING INFORMATION

Warranty Information

Watt Sto p p e r / L e g rand warranties its products to be free of defects in mate r i a l s
and workmanship for a period of five ye a rs. There are no obligations or
liabilities on the part of Watt Sto p p e r / L e g rand for consequential damages
arising out of or in connection with the use or perfo r m a n ce of this product or
other indirect damages with respect to lo ss of pro p e r t y, revenue, or profit, or
co st of re m oval, installation or re i n sta l l a t i o n .

Units come in White (-W), Light Almond (-LA), Ivory (-I), Gray (-G), Black (-B).
Add color designator to catalog number when ordering.
* One ASP-211 Cover Plate for single gang box is included with each switch.

2800 De La Cruz Bouleva rd, Santa Clara CA 95050

Te c h n i cal Support: 800.879.8585 • www. w a t t sto p p e r. co m

07115r1 10/2006

Catalog #

Description

DW-100

Dual technology wall switch sensor; 120/230/277VAC, 50/60Hz

DW-100-347 Dual technology wall switch sensor; 347VAC, 50/60Hz

DW-200

Dual technology dual relay wall switch sensor; 
120/230/277VAC, 50/60Hz

ASP-422

Blank cover plate for 2-gang box

ASP-432

Switch option cover plate for 2-gang box

Lights do not turn OFF

1 . T h e re can be up to a 30 minute time delay after the last motion is

d e te c ted. To verify proper operation, set DIP switch 1 to ON, then re s e t
s w i tches 1 and 2 to OFF to start Te st Mode. Move out of view of the
s e n s o r. The lights should turn OFF in approx i m a te ly 5 seco n d s .

2 . Verify that the sensor is mounted at le a st six feet (2 mete rs) away fro m

any heating/ventilating/air conditioning dev i ce that may cause fa l s e
d e tection. Verify that there is no significant heat source (e.g., high watta g e
light bulb) mounted near the sensor.

3 . Verify that the trimpot is not pointing at “override” (red LED on). If so,

ro ta te the trimpot to it’s middle setting (pointing up). The override setting
a l lows users to opera te the sensor as a service switch in the unlike ly
event of a fa i l u re .

4 . If the lights still do not turn OFF, call 800.879.8585 for te c h n i cal support.

Sensing motion outside desired areas

1 . S e lect PIR Sensitivity – Low (DIP switch 4 = ON) if nece ss a r y.
2 . Mask the PIR sensor’s lens to eliminate unwanted cove rage area. 
3 . A d j u st the Ultrasonic Sensitivity. Rota te trimpot co u n te rc lockwise to

re d u ce sensitivity.

Summary of Contents for WattStopper DW-100

Page 1: ...ballast HorsepowerRating each relay 1 6 HP 120VAC Time Delay Adjustment 5 to 30 minutes Walk Through Mode 3 minutes if no activity after 30 sec Test Mode 5 sec at initial power up or DIP switch reset...

Page 2: ...oad ON The relays are programmed independently for either Auto ON or Manual ON In either mode the load can be turned ON or OFF using the ON OFF button Load turns ON and OFFautomatically based on occup...

Page 3: ...to 30 minutes if the space gets heavy usage SmartSet behavior starts immediately and is refined continually as history is collected A Test Mode with a short time delay of 5 seconds is set when DIP sw...

Page 4: ...Trigger Mode The DW sensor has 4 occupancy trigger options set with DIP switches 5 and 6 Determine the appropriate option using the Trigger matrix In the Trigger Mode DIP switch setting table in order...

Page 5: ...metalbracket M a tchthem up with the holes in the wall box and tighten 4 Turn the circuit breaker ON Wait one minute then push the ON OFF button for each load and the lights will turn ON 5 Test and ad...

Page 6: ...sonic PIR Lens DIP SWITCH SETTINGS Call 800 879 8585 for Technical Support Ultrasonic Cones Ultrasonic Sensitivity Adjustment Trimpot Button Hinges Tabs DW 200 shown DW 100 has a single button and the...

Page 7: ...together the top sides of the buttonassembly Gently pull it away from the unit When the adjustments arecompleted replace the button cap by inserting its hinges into the tabs on the main unit and then...

Page 8: ...ASP 422 Blank cover plate for 2 gang box ASP 432 Switch option cover plate for 2 gang box Lights do not turn OFF 1 There can be up to a 30 minute time delay after the last motion is detected To verify...

Reviews: