Bus
Bus
Lock S+
Lock S-
External power supply –
External power
PL lock push button
E
ntrance panel number
L
ock timing
Main entrance panel
4 sec
(without configurator)
1 sec
2 sec
3 sec
Push button
6 sec
8 sec
10 sec
1
st
Entrance panel
2
nd
Entrance panel
3
rd
Entrance panel
4
th
Entrance panel
5
th
Entrance panel
6
th
Entrance panel
7
th
Entrance panel
8
th
Entrance panel
Confi guring the entrance panel
Entrance panel
No confi guration is needed in a basic installa-
tion with one entrance panel and one handset.
Confi guration is obligatory for any system ex-
tension (addition of entrance panels, handsets,
relays, special functions...).
The confi guration is performed with riders and
jumpers:
Confi guring the system
Caution: Switch the power supply OFF for 1 minute after every change of confi guration
Confi guration by jumper
1:
Do not confi gure
2:
Name-holder lighting: For permanent lighting leave
jumper 2
3:
Call confi rmation: To have call confi rmation at the
entrance panel, leave jumper 3
To cancel the call confi rmation take jumper 3 out
4:
Extra external power supply. For a power supply
outside the bus power supply take jumper 4 out
Confi guration by riders
P:
Entrance panel number
N:
Call number (do not confi gure)
T:
Lock timing
S:
Type of bell (ring tone)*
* Exception S = 9 lets the
entrance panel call all the
handsets of the same apart-
ment at the same time
28