The Radio ID is a 10-digit
code printed on a small
label on the bottom of
the pill dispenser…
Telecare Radio ID
The pill dispenser includes a radio transceiver to
communicate with the Reach IP, XT2 or Carer Response.
Pill Dispenser Alarm Test Call
Check a pill dispenser alarm is reported by letting the pill
dispenser deliver a dose, DO NOT tilt the unit to
TAKE
the
dose, and let half the
AFTER
time expire. HINT: to speed-
up the test adjust the
CLOCK
to few minutes before the
next dose time and reduce the
AFTER
time to 5 minutes.
Note: don’t forget to reset the clock/after time when the
test call is complete.
Registering the Pill Dispenser onto a Reach IP
Login to Pulse CMP (www.tynetecpulse.com) and enter the
Reach IP Serial No. in the
ALARM UNIT
view. Press the
Accessories
button and enter the Radio ID code, Location
and Equipment type. Press
Save
then
Synchronize
.
IMPORTANT
: when the pill dispenser is delivered to the
customer a test call must be made to check operation and
start the digital heartbeat.
Alternatively, with the Reach IP in normal operating mode
undo the fixing screw and remove the stand or connector
cover to access the
⚫
Power button.
Press the
⚫
Power button to enter Control Mode, then
press and hold the
button until the unit announces
“
add radio device
” then release.
Press the
⚫
button to confirm then open the lid on the pill
dispenser, press and hold all 3 buttons together until
TEST
is displayed, press button 3, the display will show
DEMO.
The Reach IP unit will sound a high beep if it’s a new
device and announce “
range test mode
”
.
Press
⚫
to confirm, or press
to step to the next
function, or press
to exit the mode.
Note: press and hold button 1 on the pill dispenser to exit
the DEMO mode.
Registering the Pill Dispenser onto an XT2
Radio device programming can only be performed from
the Advent XT2 Manager’s Panel designated as the
Controller
. Login using the Manager or Engineer password
and touch the Programming button.
Select the
Program Radio Devices
option from the
Program Setting drop-down list.
Enter the
Radio ID:
this is the 10-digit code taken from the
label on the bottom of the pill dispenser.
Enter the
Flat ID:
this is the flat number the pill dispenser is
being installed in. Enter 4-digits e.g. 0014.
Enter the
Location:
the pill dispenser is a portable device
therefore
select “no location”
from the drop-down list.
Press the
Send
button to update the XT2 system.
Perform a test call to check operation.
Registering the Pill dispenser onto a Carer Response
Refer to the Carer Response
user manual for full details
of the button functions
and how to navigate the
menus.
From the Main menu select
Programming
.
From the Programming menu select
Add transmitter
.
The display will prompt you to
Activate the transmitter…
Activate a pill dispenser alarm test call.
The Carer Response will beep and the display will change to
the
Add transmitter
menu with a box showing
No ID
.
Press
then
to select
Room
, then press
Press
to select the room number box
0000
.
Press
to select the first digit, press
to move between
the digits and press
or
to change each digit.
Press
when the correct room number is displayed.
Press
to select the alarm type box
None
.
Press
then
to select
Assistance
then press
Press the
button to select
Save
then press
The display will show
Radio ID saved to memory…
Return back to the
Main menu
and select
Quit
Perform a test call to check operation.
⚫