Setting the Filled Quantity
This is the number of doses placed in the medication tray
when filled and allows the
DOSES LEFT
display to be
shown.
After
FILLED
is displayed;
Press button
2/3
to set the
FILLED
quantity
(00 to 28)
Press button
1
to end and
BATT
will be displayed.
Setting the Battery Type
It is possible to use 4 x AA size alkaline or 4 x AA size
rechargeable batteries in the pill dispenser.
After
BATT
is displayed;
Press button
2
to select alkaline (
ALC
)
Press button
3
to select rechargeable (
NIMH
)
Press button
1
to end and
SECURE
will be displayed.
Setting the Secure Mode
With
SECURE
mode
ON
the pill shutter will be locked
except at alarm time and during the subsequent after time.
With
SECURE
mode
OFF
the shutter does not lock.
After
SECURE
is displayed;
Press button
2
to select secure mode
ON
Press button
3
to select secure mode
OFF
Press button
1
to end and
HOURS
will be displayed.
Setting the Hours Mode
The clock can be set to display the time in 12 hour AM/PM
mode or 24 hour mode.
After
HOURS
is displayed;
Press button
2
to select 12 hour clock (AM/PM)
Press button
3
to select 24 hour clock
Press button
1
to end and
DLS
will be displayed.
Setting the Daylight Saving Mode
The clock can be set to automatically /- 1 hour
every March/October for GMT/BST.
After
DLS
is displayed;
Press button
2/3
to select OFF/EU/US
Set
EU
for Europe,
US
for America or
OFF
to disable.
Press button
1
to end and
START
will be displayed.
Setting the Start Time
It is possible to delay the time at which the dispenser will
start to operate (useful if the dispenser is being filled off
site and being delivered to the user later).
After
START
is displayed the display will change to
YY
after
a few seconds;
Press button
2/3
to set the
YEAR
(00 to 99)
Press button
1
and
MM
will be displayed
Press button
2/3
to set the
MONTH
(01 to 12)
Press button
1
and
DD
will be displayed
Press button
2/3
to set the
DATE
(01 to 31)
Press button
1
and
HH
will be displayed
Press button
2/3
to set the
HOUR
(01 to 23)
Press button
1
to end and
STOP
will be displayed.
The time (HH) should be in advance of the first dose to be
dispensed for the user.
Setting the Stop Time
It is possible to stop the
dispenser’s
operation at a future
date and time. This is useful if two dispensers are being
used by one user in sequence and this ensures only one
dispenser is active at one time.
After
STOP
is displayed the display will change to
YY
after a
few seconds;
Press button
2/3
to set the
YEAR
(00 to 99)
Press button
1
and
MM
will be displayed
Press button
2/3
to set the
MONTH
(01 to 12)
Press button
1
and
DD
will be displayed
Press button
2/3
to set the
DATE
(01 to 31)
Press button
1
and
HH
will be displayed
Press button
2/3
to set the
HOUR
(01 to 23)
Press button
1
to end and
RECORD
will be displayed.
The time (HH) should be after the last dose to be dispensed
for the user. If the function is not required set the year to
99.
Record Function
The dispenser will record the actual times the previous 28
medications were dispensed.
After
RECORD
is displayed;
Press button
2/3
to scroll through the actual times the last
28 medications were taken.
Press button
1