How to install the Pill Dispenser
From new you will need to open
the battery compartment and
remove the battery isolation strip
shown in the photo here.
The display will
show “
BOOT
”
followed by the software version e.g.
“
SW-007
”
then the
battery charge level “
B 100%”
(full charge).
When the display shows “
CLOCK
” and flashes “
00:00
”
the
unit is ready to program.
There are 2 programming menus;
Menu A
contains the
basic settings and
Menu B
contains more advanced
functions. See below;
Menu A Settings
Press button
1
to cycle through the following functions;
CLOCK
DATE
DOSES
ALARMS
Press and hold button
1
for 3 seconds to exit the menu and
revert to normal operation.
Setting the Clock
Press button
1
once and
CLOCK
is displayed.
Press button
2/3
to set the time (00:00 to 23:59)
Note:
press and hold for fast forward/reverse
Press button
1
to end and
DATE
will be displayed.
Setting the Date
The
DATE
display will change to
YY
after a few secs.
Press button
2/3
to set the
YEAR
(00 to 99)
Press button
1
and
MM
will be displayed
Press button
2/3
to set the
MONTH
(01 to 12)
Press button
1
and
DD
will be displayed
Press button
2/3
to set the
DATE
(01 to 31)
Press button
1
to end and
DOSES
will be displayed.
Setting the Number of Doses per Day
The
DOSES
display will change to display the number of
doses per day after a few seconds.
Press button
2/3
to set the doses per day (00 to 24)
Press button
1
to end and
ALARMS
will be displayed.
Setting the Alarm Times for each Dose
The
ALARMS
display will change to display the time for the
first dose after a few seconds.
Press button
2/3
to set the time for the first dose
Press button
1
to end then set alarm time 2
Repeat for each alarm time, the number of alarm times is
determined by the “number of doses per day” set above.
Menu B Settings
Press and hold button
3
until
BEFORE
is displayed then
press button
1
to cycle through;
AFTER
SOUND
LIGHT
FILLED
BATT
SECURE
HOURS
DLS
START
STOP
RECORD
Press and hold button
1
for 3 seconds to exit the menu and
revert to normal operation.
Setting the Before Time
The
BEFORE
time allows medication to be taken up to 5
hours earlier than the next alarm time.
If this option is set the user may access their medication in
advance by turning the pill dispenser upside down then
back upright again
twice
in succession, the tray will rotate
one step and the next dose will become available.
Press and hold button
3
until
BEFORE
is displayed
Press button
2/3
to set the before time (00:00 = not
required, to 05:00 max)
Press button
1
to end and
AFTER
will be displayed.
Setting the After Time
The
AFTER
time sets how long the alarm sounds and the
pill shutter remains unlocked after the medication is due.
If half the
AFTER
time expires an alarm call will be
transmitted. If the full
AFTER
time expires another alarm
call will be transmitted and the pill shutter will lock shut.
After
AFTER
is displayed;
Press button
2/3
to set the after time (00:05 to 05:00)
Press button
1
to end and
SOUND
will be displayed.
Setting the Alarm Sound
The alarm
SOUND
will play to alert the user when it is time
to take their medication. It will sound every 5 seconds for
the first minute, then every 8 seconds up to 1 hour then
once a minute until the medication is dispensed or the
AFTER
time is reached, maximum 5 hours.
After
SOUND
is displayed;
Press buttons
2/3
to select the preferred sound (01 to 04).
Select 00 for no sound.
Press button
1
to end and
LIGHT
will be displayed.
Setting the Light On/Off
The
LIGHT
will flash to alert the user when it is time to take
their medication. It will flash every 5 seconds for the first
minute, then every 8 seconds up to 1 hour then once every
16 seconds until the medication is dispensed or the
AFTER
time is reached, maximum 5 hours.
After
LIGHT
is displayed;
Press button
2
for no light (display shows OFF)
Press button
3
for light (display shows ON)
Press button
1
to end and
FILLED
will be displayed.