Doc No. FM0862 issue 3 Page 3  

Normal

 

Power Saving

 

Use a terminal 

screwdriver to set 

the DIP switches

 

ON

 

DIP Switch 1 

 Configuration Settings 

OFF

: PIR configuration set using DIP switches 2 to 8.

 

 

ON

: PIR uses the Factory Config below and DIP switches 2 to 8 are ignored.

 

 

Function 

Factory Config with DIP 1 ON 

Power Saving Mode 

ON  

Period of no movement before new alarm 

20 Secs 

IDA Mode (Intelligent Door Alarm) 

Disabled 

IR Detection Sensitivity 

High 

Operation LED after Alarm 

ON 

Detection LED after Movement  

ON 

OFF Button  

Enabled 

Exit Delay 

0 Secs 

Alarm Delay 

0 Secs 

 

IMPORTANT:

 with DIP 1 ON there is no entry or exit delay before alarm. The PIR must therefore be carefully positioned so a Carer 

can switch the PIR on/off without entering the detection area. Poor placement in this mode is likely to result in false activations 
when Carers leave or enter the room. 

 

DIP Switch 2 

 Power Saving Mode 

Transmitting alarms consumes battery power.  
The PIR can be set to Power Saving Mode to extend battery life. 

OFF

: normal operation, the PIR sends an alarm (Tx) after the first  

movement detection (M) and will ignore new movement detections  
(M) for 60 seconds before a new alarm is sent.

 

ON

: power saving mode, the PIR sends an alarm (Tx) after the first  

movement detection (M) and there must be a period of 60 seconds  
with no movement detection (M) before a new alarm is sent*.

 

*Note: the period of no movement is reduced to 20 seconds with the  
Factory Config setting 

 DIP switch 1 ON. 

 

DIP Switch 3 

 Intelligent Door Alarm (IDA) Mode 

 

NOT USED

 

OFF

: normal PIR movement detection mode and DIP switch 4 is ignored.

 

ON

: enable IDA mode 

 feature not available with the floor PIR.  

Note: DIP switches 2 and 5 are ignored if DIP switch 3 is ON.

 

 

DIP Switch 4 

 Intelligent Door Alarm (IDA) Exit Delay 

 

NOT USED

 

In IDA mode this setting determines

 

the delay before an exit alarm is transmitted 

 feature not available with the floor PIR.  

Note: DIP switch 4 is ignored if DIP switch 3 is OFF.

 

 

DIP Switch 5 

 PIR Detection Sensitivity 

It is possible to adjust the sensitivity of the PIR detector by configuring the number of movement detection pulses that are needed 
before an alarm is sent. 

OFF

: high sensitivity.

 

ON

: low sensitivity.  

 

DIP Switch 6 

 Operation LED indication after Alarm 

OFF

: no indication when an alarm is sent.

 

ON

: the Operation LED will indicate when an alarm is sent.  

Note: the Operation LED will always indicate during Start-up Mode and Walk Test Mode regardless of this setting. 

 

DIP Switch 7 

 Detection LED indication after Movement 

OFF

: no indication when movement is detected.

 

ON

: the Detection LED will indicate when movement is detected.  

Note: the Detection LED will always indicate during Walk Test Mode regardless of this setting. 

 
DIP Switch 8 

 Disable OFF Button & Alarm Delay 

The function of DIP 8 depends on the position of DIP 3 (IDA mode on or off) 

With DIP 3 OFF (IDA mode not activated) 

 the OFF button can be configured and alarm delays are set 

DIP 8 OFF

: the PIR can be turned off with the OFF button. This means Carers can enter the room and press the OFF button within 

15 seconds to prevent an alarm from being sent. By pressing the ON button when unit is in OFF mode, movement alarms are 
ignored during the first 15 seconds allowing time for Carers to leave the room (i.e. when being used as a bed alarm).  

DIP 8 ON

: the PIR cannot be turned off with the OFF button, this will prevent users from unintentionally turning the PIR off. There 

is no alarm delay. 

With DIP 3 ON (IDA mode activated) 

 the OFF button can be configured and alarm delays depend on DIP 4 

DIP 8 OFF

: the door alarm can be turned off with the OFF button.  

DIP 8 ON

: the door alarm cannot be turned off with the OFF button, this will prevent users from unintentionally turning the door 

alarm off. There is no alarm delay. 

 

 

 
 

 

Summary of Contents for Tynetec ZXT494

Page 1: ...should be placed so Carers can switch the PIR on off when leaving and entering the room without passing the detection area Always perform a walk test during installation Placement Safety Instructions...

Page 2: ...ecting the Factory Config setting DIP switch 1 ON Walk Test Mode Walk test mode is used to check the detection area of the PIR To enter the walk test mode press and hold the ON button until the Operat...

Page 3: ...ode this setting determines the delay before an exit alarm is transmitted feature not available with the floor PIR Note DIP switch 4 is ignored if DIP switch 3 is OFF DIP Switch 5 PIR Detection Sensit...

Page 4: ...s the key to exit Program Mode the unit will sound a Double Beep and the front light will return to STEADY GREEN The 8 digit ID can be found on the label on the bottom of the PIR detector it will alwa...

Page 5: ...ait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent XT operator s manual Doc No FM0420 provided with the warden call system for more information on programming...

Page 6: ...ided with the portable alarm unit for more information on programming and testing radio devices Note it is assumed the PIR detection and operation LED s are both enabled The PIR detection LED will FLA...

Page 7: ...Telecare Device pull down list box prefixed with a T33 Details of the PIR selected will be displayed in the Room House Code and ID boxes below If the details shown are correct press the Delete button...

Reviews: