Doc No. FM0862 issue 3 Page 2
Infrared Detection Lens
Operation LED
Detection LED (behind lens)
ON Button
OFF Button
Removeable Cover (Batteries and Config DIP switches inside)
Squeeze both sides of
the top cover here
Slide the top cover
off this direction
ON
OFF
ON
OFF
Switch ON
Switch OFF
Hold until the LED
lights then release
Product Overview
Operation LED
; this will indicate when the PIR is switched on/off, when it is in walk test mode, if the batteries are running low and
when an alarm is transmitted.
Note: indication of when an alarm is transmitted can be switched off using DIP switch 6.
Detection LED
; this will indicate when movement is detected.
Note: indication of movement can be switched off using DIP switch 7.
Fitting the Batteries
To fit the batteries, gently squeeze both sides of the PIR in the areas marked
and slide the top cover off the base
…
Fit the two AA batteries provided
–
polarity is indicated on the PCB. Slide the top cover back into place and click closed.
Start-up Mode
When the batteries are first fitted the PIR will enter Start-up Mode and the Operation LED will
flash
green
for 45 seconds.
There is no movement detection or alarm transmissions during this period.
If the batteries are low, then the Operation LED will
flash
red
during the 45 second Start-up period. Replace both batteries.
Note: the batteries should be removed if the PIR is being stored or if it is not going be used for a prolonged period of time.
ON/OFF Buttons
To switch the PIR ON
; press and hold the ON button until the
Operation LED lights
green
then release.
All movement will be ignored for 15 seconds giving
time to vacate the detection area without raising an alarm.
There is also a delay of 15 seconds after movement is detected
until an alarm is transmitted - this gives time to enter
and switch the PIR OFF without raising an alarm*.
To switch the PIR OFF
; press and hold the OFF button until the
Operation LED lights
red
then release.
*Note: the entry/exit delay can be overridden for instant arm/alarm by selecting the Factory Config setting
–
DIP switch 1 ON.
Walk Test Mode
Walk test mode is used to check the detection area of the PIR.
To enter the walk test mode
; press and hold the ON button until the Operation LED lights
steady green
and keep holding until it
changes to
red
then release the button.
The Operation LED will then
flash red
once every 3 seconds during walk test mode.
Walk in the intended PIR coverage area and check the Detection LED behind the PIR lens
flashes red
when movement is detected.
To exit the walk test mode
; press the ON or OFF button at any time and the PIR will revert to ON mode, or if no movement is
detected for 60 seconds the PIR will revert to ON mode automatically.
Note: there are no radio alarm transmissions during walk test mode and the Detection/Operation LED
’
s are always enabled.
Low Battery Check
When the PIR is switched ON the Operation LED will normally light
green
, if the batteries are low this will be followed by 5 quick
red flashes
. Always replace both batteries together:
AA size 1.5V Alkaline (LR6)
.
A low battery check is also performed when the batteries are first fitted
–
see
Start-up Mode
above.
The PIR automatically checks the battery level every 24 hours. If the battery level is below a threshold value a low battery alarm is
sent. The Operation LED does not indicate when this alarm is sent. The first battery check is performed 1-10 minutes after Start-up.
A battery check is also performed before each radio transmission.
PIR Configuration DIP Switches
Remove the top cover to access the 8 way configuration DIP switch on the PCB inside.
DIP No.
Function
Switch OFF
Switch ON
Default
1
Configuration Settings
Config via DIP switches 2-8
Config set via factory pre-sets
ON
2
Power Saving Mode
Power saving off
Power saving on
OFF
3
IDA Mode (Intelligent Door Alarm)
IDA off
–
NOT USED
IDA on
–
NOT USED
OFF
4
IDA Exit Delay
5 Sec Delay
–
NOT USED
180 Sec Delay
–
NOT USED
OFF
5
IR Detection Sensitivity
High Sensitivity
Low Sensitivity
OFF
6
Operation LED after Alarm
LED indication off
LED indication on
ON
7
Detection LED after Movement
LED indication off
LED indication on
ON
8
Disable OFF button & Alarm Delay
Button enabled/15 Sec Delay
Button disabled/No Delay
OFF