background image

 

 
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

 

 

Page 6 of 8

 

INSTRUCTION/INSTALLATION SHEET 
lyriQ™ Studio High Performance 
Keypad

IS-0425 REV. A

 

  ©Copyright 2009 by On-Q/Legrand All Rights Reserved. 

button turns blue).  

 

In this mode, all functions performed on the local keypad such as Volume Up/Down, Mute/Un-Mute, Source 
selection, or Power On/Off are relayed to and performed on all active keypads in the system.  

 
 

NOTE: The Whole-House mode will be exited when the user fails to press a key within 10 seconds or by 
pressing the WHOLE HOUSE button again. 
 

H. DIMMING set-up: 

Press and Volume- at the same time to enter mode. Backlights will flash. Press + or – to adjust level 
of light. 
 

I.  POWER UP SELF TEST (see 

Figure 5

): 

Keypad only – When power is applied to the Studio Keypad, the following start up test will occur: 
1) The Keypad white backlight LEDs will illuminate to full intensity. 
2) The MUTE button backlight will transition to red and back to white. 
3) The WHOLE HOUSE button backlight will transition to blue and back to white. 
4) The volume indicator LEDs and then source indicator LEDs will illuminate left to right and then back to the left. 
5) The Keypad white backlight LEDs will dim to off and the Standby button will be backlit red. 
6)  When done, the Keypad powers down, 

 

NOTE: The first 5 power up self tests will take about 15 seconds, and about 2 seconds after that. Hitting any 
button during the test will interrupt the test and the Keypad will operate as normal. 
 
 

5.   Important Safety Precautions: 

 

Read the instructions that are included with all associated lyriQ™ Audio products before installing any single component. If 
you are unsure of any of the installation procedures contact On-Q/Legrand Technical Support @ 1-800-321-2343 option 1 or 
contact an On-Q/Legrand installer. 

  Do not attempt to service, move or change any component of the lyriQ™ Audio system unless you are qualified to do so. 

  This system should be installed by a qualified installer and must conform to all local building and electrical codes. 

  Do not apply power to the lyriQ™ Audio System until all components are installed and wiring is properly terminated. 

  Do not attempt to terminate, change or un-install any wiring without first turning off power to the lyriQ™ Audio System 

located in the Enclosure. Unplug the power to the lyriQ™ Audio System from the power outlet before proceeding with 
wiring terminations or changes. 

  Install all system components away from heat sources such as HVAC ducts/registers, stoves or any other heat source. 

  Do not expose any component that was designed for indoor use to moisture. Doing so can create electrical hazards or 

render the component unusable. Exposure to moisture will also void the warranty on the system. 

  Do not use vacuum cleaners, liquid or aerosol cleaners to clean system cover plates. A damp cloth may be used. 

 
 

6.   Installer Set Up Mode (see Page 7 and 8) 

Summary of Contents for On Q lyriQ

Page 1: ...by Mode for MUTE backlit with red LEDs when Mute function is selected VOLUME UP DOWN with six associated blue Volume Bar Graph LEDs SOURCE SELECT with six blue Source Selection LEDs and WHOLE HOUSE backlit with white LEDs when not selected and with flashing blue white LEDs when Whole House function is selected There is also an IR target window The visual cue from the front panel that this is a Hig...

Page 2: ...ould be run from the enclosure location to a single gang outlet box at each Volume Control location typically mounted at electrical light switch height B Trim out steps 1 Connect the volume control by terminating the pre wired Category 5 cable from the enclosure with an RJ45 plug following the T568A wiring standard and insert this plug into jack J1 see Figure 2 2 For the power connection TB1 strip...

Page 3: ...r wire power cable that was run to each volume control location strip 3 8 of insulation from each of the four conductors and insert the red and white wires into the red plus portion of TB1 Insert the stripped black and green wires into the black minus portion of TB1 NOTE As noted before Electricians may prefer to think of the black and red wires as plus and the green and white wires as minus That ...

Page 4: ...rformance Keypad IS 0425 REV A Copyright 2009 by On Q Legrand All Rights Reserved 5 Keypad Mounting check all connections and test the system s operation before installing the volume controls into the wall Use the included screws to install the volume control and wall plate into the single gang box NOTE A 20 cubic inch or larger single gang box is recommended Figure 4 ...

Page 5: ...ocal Sources If more than one Local Source is connected they are indicated by L and 2 NOTE Upon source change volume mutes and then ramps back up to prior volume setting automatically D VOLUME Steps Keypad or Remote Press VOLUME Up or VOLUME Down button 36 steps E MUTE Keypad or Remote Press MUTE button to toggle Mute On or Off NOTE When returning from MUTE volume control will ramp to pre mute or ...

Page 6: ...sts will take about 15 seconds and about 2 seconds after that Hitting any button during the test will interrupt the test and the Keypad will operate as normal 5 Important Safety Precautions Read the instructions that are included with all associated lyriQ Audio products before installing any single component If you are unsure of any of the installation procedures contact On Q Legrand Technical Sup...

Page 7: ...ed on it will be set to its last volume MAXIMUM VOLUME Sets the maximum allowed volume for this KVC SPECIFIED VOLUME DEFAULT The displayed volume setting is the maximum volume IR TARGET ENABLED IR REPEAT ENABLED DEFAULT The KVC will process received IR commands and repeat any received IR throught the system IR TARGET ENABLED IR REPEAT DISABLED The KVC will process received IR commands but will NOT...

Page 8: ...tem The KVC allows for different patterns based on the selected source 1 4 The pattern selected here will be for the source that was selected when Installer Setup Mode was activated 56 kHz FREQUENCY This KVC will repeat IR commands using a 56 kHz pattern ENABLED DEFAULT This KVC will automatically power off after 20 minutes of audio inactivity AUTOMATIC POWER OFF Determines whether this KVC will a...

Reviews: