background image

 

 
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

 

 

Page 3 of 8

 

INSTRUCTION/INSTALLATION SHEET 
lyriQ™ Studio High Performance 
Keypad

IS-0425 REV. A

 

  ©Copyright 2009 by On-Q/Legrand All Rights Reserved. 

controls the output level of this connection. 

 

4)  Connections in the enclosure (see

 

Figure 3 

): 

 
a)   The Category 5 cable that was run to each volume control location should be terminated with an RJ45 

plug according to the T568A wiring standard and inserted into one of the zone output jacks of the 
associated lyriQ™ audio distribution module. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

b)   For the 16/4 speaker wire power cable that was run to each volume control location, strip 3/8” of 

insulation from each of the four conductors and insert the red and white wires into the red (plus ) portion 
of TB1. Insert the stripped black and green wires into the black (minus) portion of TB1  

 
NOTE: As noted before, Electricians may prefer to think of the black and red wires as plus and the 
green and white wires as minus. That wiring will also work, as long as it is also followed at each 
end of the cable. 

 
c)   To connect more than eight (8) Keypads to a 4 Source 8 Zone Module, cascade Single Source Modules. 

To cascade a Single Source Module, simply run a Cat 5e jumper from any Zone port RJ45 jack on the 
front panel of the Multi-source Module to the “Source In” RJ45 jack on the front panel of a Single Source 
Module (see 

Figure 4

). 

 
 
 
 
 
 

Figure 3 

Summary of Contents for On Q lyriQ

Page 1: ...by Mode for MUTE backlit with red LEDs when Mute function is selected VOLUME UP DOWN with six associated blue Volume Bar Graph LEDs SOURCE SELECT with six blue Source Selection LEDs and WHOLE HOUSE backlit with white LEDs when not selected and with flashing blue white LEDs when Whole House function is selected There is also an IR target window The visual cue from the front panel that this is a Hig...

Page 2: ...ould be run from the enclosure location to a single gang outlet box at each Volume Control location typically mounted at electrical light switch height B Trim out steps 1 Connect the volume control by terminating the pre wired Category 5 cable from the enclosure with an RJ45 plug following the T568A wiring standard and insert this plug into jack J1 see Figure 2 2 For the power connection TB1 strip...

Page 3: ...r wire power cable that was run to each volume control location strip 3 8 of insulation from each of the four conductors and insert the red and white wires into the red plus portion of TB1 Insert the stripped black and green wires into the black minus portion of TB1 NOTE As noted before Electricians may prefer to think of the black and red wires as plus and the green and white wires as minus That ...

Page 4: ...rformance Keypad IS 0425 REV A Copyright 2009 by On Q Legrand All Rights Reserved 5 Keypad Mounting check all connections and test the system s operation before installing the volume controls into the wall Use the included screws to install the volume control and wall plate into the single gang box NOTE A 20 cubic inch or larger single gang box is recommended Figure 4 ...

Page 5: ...ocal Sources If more than one Local Source is connected they are indicated by L and 2 NOTE Upon source change volume mutes and then ramps back up to prior volume setting automatically D VOLUME Steps Keypad or Remote Press VOLUME Up or VOLUME Down button 36 steps E MUTE Keypad or Remote Press MUTE button to toggle Mute On or Off NOTE When returning from MUTE volume control will ramp to pre mute or ...

Page 6: ...sts will take about 15 seconds and about 2 seconds after that Hitting any button during the test will interrupt the test and the Keypad will operate as normal 5 Important Safety Precautions Read the instructions that are included with all associated lyriQ Audio products before installing any single component If you are unsure of any of the installation procedures contact On Q Legrand Technical Sup...

Page 7: ...ed on it will be set to its last volume MAXIMUM VOLUME Sets the maximum allowed volume for this KVC SPECIFIED VOLUME DEFAULT The displayed volume setting is the maximum volume IR TARGET ENABLED IR REPEAT ENABLED DEFAULT The KVC will process received IR commands and repeat any received IR throught the system IR TARGET ENABLED IR REPEAT DISABLED The KVC will process received IR commands but will NOT...

Page 8: ...tem The KVC allows for different patterns based on the selected source 1 4 The pattern selected here will be for the source that was selected when Installer Setup Mode was activated 56 kHz FREQUENCY This KVC will repeat IR commands using a 56 kHz pattern ENABLED DEFAULT This KVC will automatically power off after 20 minutes of audio inactivity AUTOMATIC POWER OFF Determines whether this KVC will a...