7
KEOR SPX
EN
A - Battery backup outlets
B - AC input
The models with multistandard outlets have a non-detachable power cord available with Ger-
man standard (type F), US standard (type B) and British standard (type G).
The models with IEC outlets have a detachable power cord available with German standard
(type F) and British standard (type G).
C - Fuse/Circuit breaker
D - USB communication port
E - Cooling fan
Battery backup outlets
Model
600VA
800VA
1000VA
1500VA
2000VA
IEC
x 4
x 6
Universal
x 2
x 4
3
Plug-in Equipment
Plug your equipment to Battery Backup Outlets on the rear panel of the UPS.
NOTE: Make sure that the UPS is powered on to protect all important devices from data loss during
power failure.
CAUTION: NEVER connect a laser printer or scanner to the battery backup outlets of UPS.
The equipment may draw significantly power to overload the UPS.
4
Connect Communication Port and Install Software (Optional)
Connect one end of the USB cable to PC and the other to the USB port at the rear of the UPS.
In order to monitor the UPS parameters and manage the automatic shutdown of the computer
powered by the UPS itself, it is possible to download the UPS Communicator software (Windows
only) from the website http://www.ups.legrand.com in the software section.
For additional information, download and read the UPS Communicator manual on the website.
5
Operations & Functions
1 -
Turn On the UPS: press the power switch lightly. Then, the LED will light up.
2 -
Turn Off the UPS: press the power switch again. Then, the LED will go off.
3 -
Cold Start: when the UPS is off and there is no power utility, it's still possible to turn on the UPS
unit to power the loads.