LEGRAND Celiane 670 51 Quick Start Manual Download Page 2

1. GENERAL CHARACTERISTICS

Lighting or heating control with a time delay function when switched off.

2. RANGE

3. FITTING

1 - The mechanism is clipped to the support.

2 - The rocker is clipped to the mechanism.
3 - The cover plate (supplied with rocker) is clipped to the mechanism/
rocker assembly.
4 - The plate is clipped to the support.
Can be fitted with the full range of Céliane finishes.
Vertical and horizontal multi-gang mounting.
 

4. OVERALL DIMENSIONS

5. CONNECTION

6. OPERATION

Adjustment:

Remove the rocker, then use a flat-blade screwdriver to adjust to the 
desired time delay value (from 25 seconds to 15 minutes).

Operation: 
- Press to switch on during time delay period. 
- Pressing for < 2 seconds during the time delay period restarts it. 
- Pressing for > 2 seconds during the time delay period switches off.

The switch has a LED lighting function.

87045 LIMOGES Cedex

Telephone: +33 (0)5 55 06 87 87 - Fax: +33 (0)5 55 06 88 88

Data sheet: F00547EN/ 01

Last update: 11/02/2009

Created: 01/08/2008

1/2

Cat. No(s): 670 51

Céliane

TM

 

Timer switch

Description Cat. No(s)

No. of  

modules

Connection 

method

Weight 

Characteristics

Timer 

switch

670 51

2

with 

screws

45.9

240 V

±

 

50 / 60 Hz

45

45

38.7

32.7

Number of terminals:

2

Terminal type:

with screws

Stripping length:

6 mm

Terminal capacity:

1 x 2.5 mm

2

 flexible or rigid

Tool:

Flat 3.5 mm

L

230 V

A

N

15 mi

n

25 s

*

*

*

*

* not supplied with the mechanism

≥ 

40 mm

1

2

3

4

Summary of Contents for Celiane 670 51

Page 1: ...enie przez dotknięcie palcem Do montażu w puszce o głębokości 40 mm Łącznik dotykowy z zaciskiem neutralnym 1000 W 1 0670 42 Można połączyć ze sobą maksymalnie 5 łączników dotykowych Do montażu w puszce o głębokości 40 mm Łącznik bezdotykowy z zaciskiem neutralnym 1000 W 1 0670 49 Włącza lub wyłącza oświetlenie po przesunięciu ręki przed łącznikiem Można połączyć ze sobą maksymalnie 5 łączników be...

Page 2: ...25 seconds to 15 minutes Operation Press to switch on during time delay period Pressing for 2 seconds during the time delay period restarts it Pressing for 2 seconds during the time delay period switches off The switch has a LED lighting function 87045 LIMOGES Cedex Telephone 33 0 5 55 06 87 87 Fax 33 0 5 55 06 88 88 Data sheet F00547EN 01 Last update 11 02 2009 Created 01 08 2008 1 2 Cat No s 670...

Page 3: ...30 s Voltage 240 V AC Frequency 50 60 Hz Max power 1 Resistive 2 Uncompensated fluorescent 3 Compensated fluorescent 4 Incandescent 5 Compact fluorescent and fluorescent with electronic transformer 6 Fan motors 7 ELV halogen with ferromagnetic transformer 8 ELV halogen with electronic transformer 7 4 Climatic characteristics Storage temperatures 10 C to 60 C Operating temperatures 5 C to 50 C 8 CL...

Page 4: ...lichting wordt uitgeschakeld Connect the devices on the same phase If lighting is on after the first installation of the product without any key operation then press the switch for more than 2 seconds Lighting then goes off Die Geräte müssen phasengleich angeschlossen werden Falls nach der ersten Installation die Beleuchtung ohne Tastenbetätigung eingeschaltet ist betätigen Sie den Schalter länger...

Page 5: ...tly removed and disposed of in accordance with national legislation and the requirements of environmental protection Das Gerät enthält eine LiMgO2 Primärzelle Diese muss nach Produktlebensdauer fachgerecht entnommen und nach den landesspezifischen gesetzlichen Bestimmungen umweltgerecht entsorgt werden El aparato contiene una pila botón no recargable de LiMgO2 Una vez agotada la vida útil del prod...