background image

For more information visit www.legrand.us/cablofil

18

Pour plus de détails, visiter www.legrand.us/cablofil

Para obtener información adicional visite www.legrand.us/cablofil

19

SWEEPS: SWK & EZ BN 1/4 / CE25 / ED275

COURBES À GRAND RAYON : SWK ET EZ BN 1/4/CE25/ED275 / 

CURVAS: SWK Y EZ BN 1/4/CE25/ED275

SWEEPS: FASLOCK 

COURBES À GRAND RAYON : FASLOCK / CURVAS: FASLOCK

x6

x10

x9

x12  

   

  

12" (300 

MM

)

   

  

20" (500 

MM

)

   

  

18" (450 

MM

)

   

  

24" (600 

MM

)

X

6

X

10

FASLOCK*

X

8

FASLOCK XL 

FASLOCK XL

X

12

FASLOCK XL  

27.6"

700 

MM

15.8"

400 

MM

R

42.5"

1080 

MM

24.8"

630 

MM

R

47.6"

1210 

MM

28"

710 

MM

R

57.7"

1465 

MM

34.1"

865 

MM

R

x2

x3

x3

Sweeps can be formed easily on site by cutting some of 
the side and bottom wires. Use the FASLOCK method 
to secure desired curve.

Il est possible de former aisément des courbes à grand rayon 
sur place en coupant certains des fils de treillis latéraux et 
inférieurs. Utiliser la méthode FASLOCK pour obtenir la courbe 
souhaitée.

Las curvas pueden formarse fácilmente en la obra cortando 
algunos de los alambres laterales e inferiores. Use el método 
FASLOCK para asegurar la curva deseada.

   

  

4” (100 

MM

)

   

  

6” (150 

MM

)

   

  

8" (200 

MM

)

X

2

FASLOCK  S      

X

3

FASLOCK  S   

X

4

FASLOCK S

11.9"

303 

MM

5.6"

142 

MM

R

17.0"

433 

MM

8.7"

221 

MM

R

21.9"

557 

MM

11.8"

300 

MM

R

*Use FASLOCK S for CF54/100, 150, 200, 300, CF105/100, 150, 200. Use FASLOCK XL for all other larger sizes. 

*Utiliser un FASLOCK S pour les CF54/100, 150, 200, 300, CF105/100, 150, 200. Utiliser un FASLOCK XL pour toutes les autres tailles plus grandes.
*Use FASLOCK S para CF54/100, 150, 200, 300, CF105/100, 150, 200. Use FASLOCK XL para los demás tamaños más grandes.

*Use bolt cutters to 
cut to fit.

*Utiliser des coupe-
boulons pour couper de 
façon à ajuster.

*Use los cortapernos 
para cortar a la medida.

x3

x3

x4

   

  

4" (100 

MM

)

   

  

6" (150 

MM

)

   

  

8" (200 

MM

)

x2

x1

x2

EZ BN 1/4

CE 25

ED 275*

X

3

x2

x1

x2

EZ BN 1/4

CE 25

ED 275*

X

3

x2

x1

x2

EZ BN 1/4

CE 25

ED 275*

X

2

x1

SWK

x2

   

  

2" (50 

MM

)

x4

x1

x4

EZ BN 1/4

CE 25

ED 275*

X

3

7.5"

190 

MM

5.5"

140 

MM

R

12.6"

320 

MM

8.7"

220 

MM

R

17.7"

450 

MM

11.8"

300 

MM

R

17.7"

450 

MM

9.8"

250 

MM

R

Sweeps can be formed easily on site by cutting some of 
the side and bottom wires. Use the SWK method to secure 
desired curve. Always place bolt heads to inside of tray to 
prevent frayed wires.

Il est possible de former aisément des courbes à grand rayon sur 
place en coupant certains des fils de treillis latéraux et inférieurs. 
Utiliser la méthode SWK pour obtenir la courbe souhaitée.
Toujours placer la tête des boulons à l’intérieur du chemin pour 
empêcher un éraillage des fils de treillis.

Las curvas pueden formarse fácilmente en la obra cortando algunos 
de los alambres laterales e inferiores. Use el método SWK para asegu-
rar la curva deseada. Coloque siempre las cabezas de los pernos en el 
interior de la bandeja para impedir que se desgasten los alambres.

1

A

2

B

   

  

12" (300 

MM

)

   

  

20" (500 

MM

)

   

  

18" (450 

MM

)

   

  

24" (600 

MM

)

x2

x1

x2

EZ BN 1/4

CE 25

ED 275*

x2

x1

x2

EZ BN 1/4

CE 25

ED 275*

X

4

X

9

X

6

X

11

X

2

X

2

x1

SWK

x1

SWK

x1

SWK

x1

SWK

x6

x9

x8

x11

27.6"

700 

MM

15.8"

400 

MM

R

37.4"

950 

MM

19.7"

500 

MM

R

42.5"

1080 

MM

22.8"

580 

MM

R

52.8"

1340 

MM

29.1"

740 

MM

R

Summary of Contents for Cablofil

Page 1: ...GUIDE WIRE MESH TRAY GUIDE D INSTALLATION CON U POUR TRE MEILLEUR U A DE INSTALACI N DISE ADAS PARA SER MEJORES INSTALLATION...

Page 2: ...NTAJES DE TECHO UNDER FLOOR MOUNTINGS 29 30 MONTAGES SOUS PLANCHER MONTAJES DE DEBAJO DEL PISO OTHER MOUNTING 30 31 AUTRE MONTAGE OTROS MONTAJES Cablofil the inventor of wire mesh cable tray is a revo...

Page 3: ...d u s tr ie c h im iq u e R e n e r a s d e p e tr le o P la n ta s q u m ic a s M a r i n e s a l t W e a k s u l p h u r o u s e n v i r o n m e n t s E n v ir o n n e m e n ts d e s e l m a r in f...

Page 4: ...s when using power equipment Proc der comme indiqu la page pr c dente lorsqu on utilise un Cuty l Ne pas oublier de tou jours porter des lunettes tanches et de respecter les r gles suivre pour assurer...

Page 5: ...600 MM PRECLICK splices needed on side wires Jonctions PRECLICK n cessaires sur les ls de treillis lat raux Se necesitan empalmes PRECLICK en alambres laterales 2x PRECLICK 2x PRECLICK 2x PRECLICK SWK...

Page 6: ...RGEUR CHEMIN ANCHO DE LA BANDEJA QTY REQUIRED QT N CESSAIRE CANT REQUERIDA CUT INSTRUT INSTRUCT COUPE INSTRUCT CORTE QTY REQUIRED QT N CESSAIRE CANT REQUERIDA CUT INSTRUT INSTRUCT COUPE INSTRUCT CORTE...

Page 7: ...N 1 4 CE 25 EZ T 9O X2 x4 x1 x4 EZ BN 1 4 CE 25 EZ T 9O X2 x4 x1 x4 EZ BN 1 4 CE 25 EZ T 9O X2 One RAD T 90 KIT will make one T Junction Un seul kit RAD T 90 permet d effectuer une jonction en t Un JU...

Page 8: ...2 EZ BN 1 4 CE 40 X1 x4 x4 EZ BN 1 4 CE 25 x1 EZ T 9O x1 x2 EZ BN 1 4 CE 40 X1 x4 x4 EZ BN 1 4 CE 25 x1 EZ T 9O x1 x2 EZ BN 1 4 CE 40 X1 x2 x1 x2 x2 x2 x1 x2 x2 x2 x3 x2 x3 One RAD T 90 KIT will make...

Page 9: ...IONS AUTRES QU ANGLE DROIT OTRAS UNIONES QUE NO SEAN DE 90 x4 x5 x6 18 450 MM 20 500 MM 24 600 MM x4 x4 EZ BN 1 4 CE 25 x1 EZ T 9O x1 x2 EZ BN 1 4 CE 40 X1 x4 x4 EZ BN 1 4 CE 25 x1 EZ T 9O x1 x2 EZ BN...

Page 10: ...autres tailles plus grandes Use FASLOCK S para CF54 100 150 200 300 CF105 100 150 200 Use FASLOCK XL para los dem s tama os m s grandes Use bolt cutters to cut to t Utiliser des coupe boulons pour co...

Page 11: ...h hiVcYVgY YZ 8VWad a HL 9GC O7C 9I OI G69I hdci Xdc jZh edjg Vkd g jcZ g h hiVcXZ c g ZjgZ b aa d b entre connexions et assurent une liaison lectrique entre les sections Ces jonctions ont t test es p...

Page 12: ...una conexi n a tierra entre secciones UL ha probado estos empalmes como parte del sistema de conexi n a tierra de la bandeja portacables La bandeja de malla de cable pintada Cablofil requiere retirar...

Page 13: ...2 O 600 mm MAX 2 O 2 0 610mm 2 0 610mm 2 0 610mm W 2 0 610mm Horizontal Cross Support Support de jonction transversale horizontale Soporte transversal horizontal On 24 wide items recommended distance...

Page 14: ...SPLICE JONCTION EMPALME EDT SPLICE PLATE PLAQUE DE JONCTION PLACA DE EMPALME EDRSKIT TRAY REDUCTION KIT KIT DE R TR CISSEMENT DE CHEMIN JUEGO DE REDUC CI NDE BANDEJAS ED 275 UNIVERSAL SPLICE BAR BARR...

Page 15: ...RAL DE SUSPENSION SOPORTE COLGANTE CENTRAL PAT 30 SUSPENSION SHOE PATIN DE SUSPENSION ZAPATA DE SUSPENSI N FAS PCH CENTER HANGER SUPPORT CENTRAL DE SUSPENSION SOPORTE COLGANTE CENTRAL FAS C BRACKET SU...

Page 16: ...EMIN SUR POUTRE SOPORTE DE VIGA DE BANDEJA CC KIT CONDUIT CLAMP KIT KIT DE COLLIERS DE TUBE PROTECTEUR JUEGO DE ABRAZADERAS DE CONDUCTOS CM50I INDUSTRIAL BOX MOUNTING BRACKET SUPPORT DE MONTAGE DE COF...

Page 17: ...www legrand us cablofil Phone 800 658 4641 618 566 3230 Fax 618 566 4978 8319 State Route 4 Mascoutah IL USA 62258 O...

Reviews: