Parameter
Function
Event Type
It includes local alarm/network alarm.
- Local alarm: Device detects alarm from input port.
- Network: Device detects alarm from network.
Alarm in
Select corresponding alarm channel.
Enable
Check to enable the alarm function.
Type
There are two options: normal open and normal close.
NO becomes activated in low voltage, NC becomes activated in high voltage..
Period
- Alarm record function becomes activated in the specified periods.
- There are six periods in one day. Enable corresponding period.
- Select date or whole week.
- Click OK button, system goes back to alarm setup interface, please click save button to exit.
Anti-dither
System only memoryze one alarm during the period set here (0 to 600 s)
Normal Out
Select alarm output port so that system can activate corresponding alarm device when
alarm occurs.
Alarm Latch
System delay the alarm output for specified time after alarm end (from 10 seconds to 300
seconds).
Record Channel
System auto activates current channel to record once alarm occurs (working with alarm
activation function). Note current device shall be in auto record mode (Chapter 8.2.3
Schedule).
Record Latch
System can delay the record for specified time after alarm ended.
The value ranges from 10s to 300s.
Check to enable email function. System can send email when alarm occurs and ends.
Tour
This function is not available in current device.
PTZ activation
The system can go to a preset when alarme occurs (only for IP speed dome).
Capture
Input capture channel number so that system can backusnapshot file to the SD card or send
to the specified email box when alarm occurs.
Copy
It is a shortcut menu button. You can copy current channel setup to one or more (all)
channels.
Save
You can click save button after you complete setup for one channel, or you can complete
the whole setups and then click save button.
Refresh
Click this button to get device latest configuration information.
Summary of Contents for 4 360 61