Parameter
Function
RS232 COM
You can use the COM or mini terminal to upgrade and debug the
software.
Function
You can use special keyboard to control device via COM.
Data Bit
The value ranges from 5 to 8.
Stop Bit
There are three options: 1/1.5/2.
Baud Bit
You can select corresponding baud bit here.
Parity
There are four options: none/odd /mark/space.
System default setup is:
RS232: COM01
Baud rate: 115200
Data bit: 8
Stop bit: 1
Parity: None.
Network
Network interface is shown as below.
Please refer to the following sheet for detailed information.
Parameter
Function
Ethernet
Please select the network card first.
IP Address
The IP address of this device, user can set the IP address according to
his actual requirements. then set subnet mask, gateway correspondingly.
DHCP
Dynamically get IP address. You can get the device IP from the DHCP
server if you enabled this function.
Device Name
Default name is NVD. You can input a new one if necessary.
TCP Port
Default value is 37777.
HTTP Port
Default value is 80.
UDP Port
Default value is 37778.
Max Connection
Network user max amount. The value ranges from 1 to 10.