background image

21

36 x / Auto Focus ICR Camera

Pick-up Device

1/4” High Resolution Super HAD II WD CCD (Sony Chipset)

Total pixels No

NTSC: 1 028 (H) x 508 (V) 520K      -    PAL: 1 028 (H) x 596 (V) 610K

Effective pixels No

NTSC: 976 (H) x 494 (V) 480K      -       PAL: 976 (H) x 582 (V) 570K

S/N Ratio

> 50dB

Horizontal resolution

> 550 TV lines

Lens

36 x Zoom (f= 3.4 mm ~ 122.4 mm, F1.6~ 4.5), Video AF

Min. Shooting distance

0.1 (WIDE), 1.5 m (TELE)

Min Illumination

Normal mode: 0.03 Lux, Night mode: 0.01 Lux

Digital zoom ratio

Basic x16 (total zoom ratio x 576) x 2 ~ x16 variable

Synchronous system

Internal/External (Line Lock)

OSD (On Screen Display)

OSD On 

(Menu, Zoom, Focus, WBC, BLC, Shutter, CAM ID, User Title) / Off

Video Output

Composite video 1 Vp-p, 75 Ohms

Camera control

RS-232 (TTL Level, 2.4K/ 4.8K/ 

9.6K

/ 19.2K/ 38.4K/ 57.6K/ 115.2K BPS)

Zoom speed

8 s mode

 / 10 s mode/ 15 s mode

Focus mode

Auto / Manual / Push Auto

White balance

Auto

 / Indoor / Outdoor / Manual / 

Push Auto

Brightness control

Manual (Brightness Up / Down)

Gain control

Auto

 / Manual

Day / Night mode

AE

 / Day / Night / External

Shutter speed

NTSC: 1/60 ~ 1/100.000, PAL: 1/50 ~ 1/100,000 include flickerless 

(NTSC: 1/100, PAL/ 1/120)

Alarm Output (Motion detection)

Active: 5V / 10 mA, Non active: 0V

Privacy Masking

15 free areas (area is adjustable)

Back light compensation

On/Off (level & area: user define and 7 default area for adjustable)

WDR (Wide Dynamic Range)

On/Off (Level adjustable), Auto detection

Day & Night (ICR)

AE / Day / Night / EXT

DNR (Digital Noise Reduction)

Low / MID / HIGH

Mirror

Off / Horizontal / Vertical / Rotate

Camera ID

000 ~ 255

Camera title

Up to 16 characters

Freeze

On / Off

Wide burst

On / Off

Gamma characteristic

0.45

Digital slow shutter

Off, 2 ~ 20, 40, 80, 160, 256, 512

Remote control

RS-485 / RS-422

Protocol

PELCO D&P

Audio output

2 Vp-p, 50 Ohms

OSD language

English 

Zoom / Focus preset

128 preset (store with internal EEPROM)

Key control

6-pin Dry Contact Connector: Tele, Wide, Near, Far, Menu, GND

Operating temperature

-10 °C ~ 50 °C

Operation humidity

0 % RH ~ 60 % RH

Supplied voltage

DC 12 V ± 10 % (recommandation DC 12 V ± 0,5 V)

Power consumption

Max 4,5W

9.  SPECIFICATIONS

* Letters in BOLD = Default mode

Note: Design and specifications are subject to change without prior notice.

Summary of Contents for 4 305 34

Page 1: ...LE04246AA 36 x Auto Focus ICR Camera 4 305 34...

Page 2: ...Digital zoom operation 14 8 2 OSD On Screen Display Main Menu Description 14 8 2 1 Main menu display 14 8 2 2 Main menu setup 14 8 3 Sub Menu Description 14 8 3 1 FOCUS Setup 14 8 3 2 EXPOSURE Setup 1...

Page 3: ...on The installation and calibration must be carried out by highly skilled personnel Do not open there may be a risk of electric shock Use only for the following temperature conditions from 5 to 50 C D...

Page 4: ...distance Current applications include highway traffic control plus security surveillance in such locations as elevators and parking lots The advanced DSP technology allows intelligent control for cle...

Page 5: ...e When in low light reducing the image frame refresh rate and increase the sensitivity of the camera Privacy mask Privacy image masking with free position support up to 15 areas of privacy masking zon...

Page 6: ...em description Item picture Camera box type Power adaptor User s manual Cam ra ICR mise au point automatique 36 x 36 x ICR Camera met automatische scherpstelling 36 x Auto Focus ICR Camera 36 x Auto F...

Page 7: ...o 1 Vp p 75 Ohms RCA 5 5 Keys control Name Function Tele Zoom tele or up Wide Zoom wide or down Near Focus near or increase Far Focus far or decrease Menu Enter or exit setup menu 6 Remote controller...

Page 8: ...ht mode is set to External on the OSD menu of the camera this function will be switched to Day mode or Night mode according to the Day Night signal from the external light sensor or the IR Led Lamp Op...

Page 9: ...t on the rear panel of the camera to a monitor 6 INSTALLATION 6 1 Connect to monitor Since the power specification supports both AC and DC you may connect an AC 24V 500 mA adaptor or a DC 12V 500mA ad...

Page 10: ...10 To connect the keyboard and alarm please follow the setup guide shown below 6 3 Connection layout 6 3 1 Connecting the Keyboard T R T R T T RS 485 2 wires to keyboard Keyboard Monitor Camera...

Page 11: ...0 38 400 57 600 115 200 Parity None The speed of camera should be the same as the speed of the keyboard Adjusted function is only effective after exiting the OSD Setup menu Note Maximum cable distance...

Page 12: ...NI GND INPUT Camera IR Illuminator Camera control Output signal 5V 10 mA Note CAM must be set to AE mode light sensor to EXT mode Alarm Installation Connect GND and AL of the camera to the GND and AL...

Page 13: ...tion 7 1 1 Normal display mode Keyboard Camera function Open Brightness Close Brightness Near Focus Near Far Focus Far Twist Joystick Clockwise Zoom In Zoom Tele Twist Joystick Counter Clockwise Zoom...

Page 14: ...control buttons to select each item Use control buttons to change the data Use Menu Control button to Enter Exit the menu display 8 3 Sub Menu description 8 3 1 Focus setup FOCUS FOCUS MODE PUSH AUTO...

Page 15: ...f the observation Otherwise select Manual mode the system will follow the focus distance previously set DEFAULT SET If initial mode set to ON all focus function is changed to the factory setting RETUR...

Page 16: ...rs optimal brightness level Therefore in dark scene highter the value higher the brightness level total of 25 levels Off 512 Default Setup OFF Note Adjust according to the environment high DSS level r...

Page 17: ...anual otherwise it is an NA not available item Default setup NA PUSH AUTO When WB Mode is set to Push Auto Push Auto ON Enable auto tracing white balance Push Auto OFF Disable auto tracing white balan...

Page 18: ...RETURN Return to previous status 8 3 6 EFFECT Setup EFFECT DISPLAY SHARPNESS 8 POSI NEGA POSI MIRROR OFF FREEZE OFF WIDE BURST OFF SYNC INTERNAL V PHASE NA DEFAULT ON RETURN DISPLAY DISPLAY TITLE EDIT...

Page 19: ...e set to POSI Positive image or NEGA Negative image Default setup POSI MIRROR Four types of Mirror Mode OFF HORIZONTAL VERTICAL ROTATE Default setup Off FREEZE Set Freeze to ON to enable still field i...

Page 20: ...after the motion alarm can be set to 5 s 10 s 15 s 20 s 30 s 1 mn 2 mn 3 mn 4 mn 5 mn Default setup 5 s When an alarm has been triggered it sends out a high level 5V signal from the rear panel ALARM...

Page 21: ...Day Night mode AE Day Night External Shutter speed NTSC 1 60 1 100 000 PAL 1 50 1 100 000 include flickerless NTSC 1 100 PAL 1 120 Alarm Output Motion detection Active 5V 10 mA Non active 0V Privacy...

Reviews: