background image

14

8.1 Digital zoom operation

The built-in 36x optical zoom lens is highly reliable and offfers auto focus and auto iris functions. 
Users can monitor a scene from any desired angle of view, use   (T)/   (W) button to control the optical zoom 
1x ~ 36x and digital zoom 1x ~ 16x.

8.2 OSD (On Screen Display) main menu description
8.2.1 Main Menu Display

MAIN MENU

FOCUS

<-->

EXPOSURE

<-->

DAY/NIGHT

<-->

WHITE BALANCE

<-->

PRIVACY MASK

<-->

EFFECT

<-->

MOTION DETECT

<-->

COMMUNICATION

<-->

DEFAULT

<-->

RETURN

ON 

8.2.2 Main Menu Setup

- In order to display the setup menu on the screen, set the menu command or press the button panel.
- Use   (T)/   (W) control buttons to select each item.
- Use   (-)/   (+) control buttons to change the data.
- Use Menu Control button to Enter/Exit the menu display.

8.3 Sub Menu description
8.3.1 Focus setup

FOCUS

FOCUS MODE

PUSH AUTO

DISTANCE

1.5 M

ZOOM START

X1

ZOOM END

X576

ZOOM SPEED

HIGH

TRACKING MODE

AUTO

DEFAULT

ON

RETURN

FOCUS MODE SET:

This function is for focus mode setting.

Set the mode to Auto, Manual, or 

Push Auto.

Note: 

Auto:  

 

Select auto mode to enable automatic adjustment of the focus position.

Push Auto:  

Select push auto to adjust focus position TELE or WIDE, the preset value 

   

 

becomes that for AF mode and returns to Manual Focus mode.

FOCUS DISTANCE SET:

This function is for selection of minimum shooting distance.

Set the focus distance mode to 10 cm, 50 cm, 1 m, 

1.5 m

, 3 m, 5 m or 10 m.

8. SYSTEM SETUP

Summary of Contents for 4 305 34

Page 1: ...LE04246AA 36 x Auto Focus ICR Camera 4 305 34...

Page 2: ...Digital zoom operation 14 8 2 OSD On Screen Display Main Menu Description 14 8 2 1 Main menu display 14 8 2 2 Main menu setup 14 8 3 Sub Menu Description 14 8 3 1 FOCUS Setup 14 8 3 2 EXPOSURE Setup 1...

Page 3: ...on The installation and calibration must be carried out by highly skilled personnel Do not open there may be a risk of electric shock Use only for the following temperature conditions from 5 to 50 C D...

Page 4: ...distance Current applications include highway traffic control plus security surveillance in such locations as elevators and parking lots The advanced DSP technology allows intelligent control for cle...

Page 5: ...e When in low light reducing the image frame refresh rate and increase the sensitivity of the camera Privacy mask Privacy image masking with free position support up to 15 areas of privacy masking zon...

Page 6: ...em description Item picture Camera box type Power adaptor User s manual Cam ra ICR mise au point automatique 36 x 36 x ICR Camera met automatische scherpstelling 36 x Auto Focus ICR Camera 36 x Auto F...

Page 7: ...o 1 Vp p 75 Ohms RCA 5 5 Keys control Name Function Tele Zoom tele or up Wide Zoom wide or down Near Focus near or increase Far Focus far or decrease Menu Enter or exit setup menu 6 Remote controller...

Page 8: ...ht mode is set to External on the OSD menu of the camera this function will be switched to Day mode or Night mode according to the Day Night signal from the external light sensor or the IR Led Lamp Op...

Page 9: ...t on the rear panel of the camera to a monitor 6 INSTALLATION 6 1 Connect to monitor Since the power specification supports both AC and DC you may connect an AC 24V 500 mA adaptor or a DC 12V 500mA ad...

Page 10: ...10 To connect the keyboard and alarm please follow the setup guide shown below 6 3 Connection layout 6 3 1 Connecting the Keyboard T R T R T T RS 485 2 wires to keyboard Keyboard Monitor Camera...

Page 11: ...0 38 400 57 600 115 200 Parity None The speed of camera should be the same as the speed of the keyboard Adjusted function is only effective after exiting the OSD Setup menu Note Maximum cable distance...

Page 12: ...NI GND INPUT Camera IR Illuminator Camera control Output signal 5V 10 mA Note CAM must be set to AE mode light sensor to EXT mode Alarm Installation Connect GND and AL of the camera to the GND and AL...

Page 13: ...tion 7 1 1 Normal display mode Keyboard Camera function Open Brightness Close Brightness Near Focus Near Far Focus Far Twist Joystick Clockwise Zoom In Zoom Tele Twist Joystick Counter Clockwise Zoom...

Page 14: ...control buttons to select each item Use control buttons to change the data Use Menu Control button to Enter Exit the menu display 8 3 Sub Menu description 8 3 1 Focus setup FOCUS FOCUS MODE PUSH AUTO...

Page 15: ...f the observation Otherwise select Manual mode the system will follow the focus distance previously set DEFAULT SET If initial mode set to ON all focus function is changed to the factory setting RETUR...

Page 16: ...rs optimal brightness level Therefore in dark scene highter the value higher the brightness level total of 25 levels Off 512 Default Setup OFF Note Adjust according to the environment high DSS level r...

Page 17: ...anual otherwise it is an NA not available item Default setup NA PUSH AUTO When WB Mode is set to Push Auto Push Auto ON Enable auto tracing white balance Push Auto OFF Disable auto tracing white balan...

Page 18: ...RETURN Return to previous status 8 3 6 EFFECT Setup EFFECT DISPLAY SHARPNESS 8 POSI NEGA POSI MIRROR OFF FREEZE OFF WIDE BURST OFF SYNC INTERNAL V PHASE NA DEFAULT ON RETURN DISPLAY DISPLAY TITLE EDIT...

Page 19: ...e set to POSI Positive image or NEGA Negative image Default setup POSI MIRROR Four types of Mirror Mode OFF HORIZONTAL VERTICAL ROTATE Default setup Off FREEZE Set Freeze to ON to enable still field i...

Page 20: ...after the motion alarm can be set to 5 s 10 s 15 s 20 s 30 s 1 mn 2 mn 3 mn 4 mn 5 mn Default setup 5 s When an alarm has been triggered it sends out a high level 5V signal from the rear panel ALARM...

Page 21: ...Day Night mode AE Day Night External Shutter speed NTSC 1 60 1 100 000 PAL 1 50 1 100 000 include flickerless NTSC 1 100 PAL 1 120 Alarm Output Motion detection Active 5V 10 mA Non active 0V Privacy...

Reviews: