Safety Tips, Care and Maintenance

Safety Tips

If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to 
applying flame, otherwise you will void the warranty.

Cover drain openings to avoid losing small parts.

When cutting or soldering pipe, use safety glasses to protect your eyes.

Important Points

Prior to beginning installation. turn off the cold and hot water lines and open the old faucet to release
built-up pressure.

Overtightening nuts may cause damage.

Wrap all threaded connections with pipe tape available at your local plumbing supply store.
Always wrap in a clockwise direction. The fittings should be installed by a state-licenced plumber.

Please note:
When there is a difference in water pressure between hot and cold supplies to the mixing valve, the 
pressures should be equalized by a plumber in accordance with best practice and legislation.

Maintenance

Your new bathroom faucet is designed for years of trouble-free performance. Keep it looking new by 
cleaning it periodically with a soft cloth. Avoid abrasive cleaners, wire wool and harsh chemicals as 
these will dull the finish and void your warranty.

Routine Maintenance

The frequency and extent of attention required will vary according to prevailing site and operational 
conditions, however a 12 monthly maintenance schedule is recommended.

If the product has operated satisfactorily for some time, but performance has been degraded, please 
check the Fault Finder section to identify the problem.

Maintenance Check List

 s 7ORNORDAMAGEDSEALSANDWASHERS
 s $AMAGEDSEALFACES
 s 4HREADWEAR
 s )NCORRECTADJUSTMENT
 s #OMPONENTFAILURE
 s $EBRISORLIMESCALEBUILDUP

Summary of Contents for M2-4406

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M2 4406 CROSS HANDLE THERMOSTATIC WITH TWO CROSS HANDLE FLOW CONTROLS TRIM ONLY TO SUIT K1 4202 ROUGH...

Page 2: ...2 Contents Dimensions 3 InstalLation Procedure 4 Parts List 7 Fault Finder 8 Safety Tips Care and Maintenance 9 Guarantee 10...

Page 3: ...4 7 16 112mm 2 1 2 3 1 2 64mm 89mm 1 3 4 45mm 1 4 6mm 5 7 8 150mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without...

Page 4: ...er supply before installation 1 Before installing the valve into the wall please note that a distance between 80mm 105mm from the wall surface to the rear of the valve should be left so that the trim...

Page 5: ...installation 5 Take out the stopper 6 Turn on the ow controller Turn the thermostatic cartridge until the water temperature is at 38 Suggestion attach a hose to the outlet and guide water to basin or...

Page 6: ...g products be installed by a licensed professional Shut off main water supply before installation 9 Fix the front plate with screws 10 Fix the canopy with screw When it is xed check that the temperatu...

Page 7: ...6 Sleeve 041724 7 Back plate 006571 51 8 Oil seal 068338 9 Pin 003153 10 Spring 005157 11 Button 036276 12 Cross handle 029685 51 13 Set screw 292598 14 Screw 008994 15 Canopy 018421 50 16 Screw 0087...

Page 8: ...Fault Finder Fault Cause Recti cation Wobbling of handle The xing screw comes loose Check for xing screw and re tighten it properly Wobbling of canopy The canopy comes loose Check and tighten the cano...

Page 9: ...ater pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is...