![Lefroy Brooks M2-4406 Installation, Operating, & Maintenance Instructions Download Page 4](http://html1.mh-extra.com/html/lefroy-brooks/m2-4406/m2-4406_installation-operating-and-maintenance-instructions_1868362004.webp)
REMOVE CAP ONLY, KEEP THE REST OF THE
MUD GUARD AS IT IS NEEDED TO HOLD THE
TRIM FIXING SCREWS.
1
2
3
4
80mm~105mm
Wall surface
HOT WATER - IN
mixed water out #1
mixed water out #2
COLD WATER - IN
140mm
96mm
58mm
Ø50mm
R14mm
99mm
4
Steps 1-4
Installation Procedure
Lefroy Brooks always recommends that plumbing products be installed by a licensed professional.
Shut off main water supply before installation.
1
Before installing the valve into the wall, please note that a distance between 80mm~105mm
from the wall surface to the rear of the valve should be left so that the trim can be fitted
correctly.
2
Install valve assembly into the wall.
3
Cut a hole on the wall surface for fitting the trim kit. The hole dimension is as shown in figure 3.
4
Throw away the protective caps only when building construction is completed and you are ready
to fit the trim kit in.
REMOVE CAP ONLY, KEEP THE REST OF THE MUD GUARD AS IT IS NEEDED TO HOLD THE TRIM
FIXING
SCREWS.