background image

2-1 5/16-16UN-2B

2-3/4-14NPSM-2A

5 1/2"

(140mm)

33 3/4"

(857mm)

1 3/4"

0~5 7/8"

(45mm)

(0~150mm)

2-Ø3 7/8"

(2-Ø99mm)

2-Ø2 7/8"

(2-Ø73mm)

Ø13/16"

(Ø20.4mm)

3

Dimensions

   

in Inches (& Millimetres)

Whilst every effort is made to ensure accuracy, design and dimensions are subject to change without 
notice as part of the company’s product development process.

Summary of Contents for C1-2666

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS C1 2666 BATH STANDPIPES INCLUDING LEGS EXTENDED UNION INTERNAL COPPER 1 PAIR TO SUIT M1 2650 M1 2600 M1 2675 ...

Page 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9 ...

Page 3: ... 0 5 7 8 45mm 0 150mm 2 Ø3 7 8 2 Ø99mm 2 Ø2 7 8 2 Ø73mm Ø13 16 Ø20 4mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without notice as part of the company s product development process ...

Page 4: ...ed professional Shut off main water supply before installation 1 Make sure that main water supply is shut off before further installation Remove plugs from valves 2 Install the standing pipe to the rough Slide the inner pipe onto the top adaptor of the rough Fix the standing pipes to the rough with the screws provided ...

Page 5: ...nstallation 3 Slide down decorative cap until it flush with floor Fix decorative cap to the stand pipe with set screws 4 Adjust stand pipes direction and install the faucet of choice model shown is for example only to the stand pipes Screw the nut tightly to seal securely 5 Finish installation by tightening the set screws on the cranked legs to fix it to the stand pipes ...

Page 6: ...d leg 020205 4 Allen key 031017 5 O ring 004098 6 Set screw 065154 7 Flange 071496 9 10 2 8 12 13 6 7 5 1 3 4 11 8 Oil seal 068030 9 Leg 064318 10 Inner pipe 064319 11 Screw 075083 12 Screw 008003 13 O ring 004010N 6 Parts List Exploded view ...

Page 7: ...7 Fault Finder Fault Cause Rectification Leaks around the connection between legs and faucet Gasket is misfitted or damaged Check for gasket placement ...

Page 8: ...e in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is designed for years of trouble free performance Keep it looking new by cleaning it periodically with a soft cloth Avoid abrasive cleaners wire wool and harsh chemicals as these will dull the fini...

Page 9: ... them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The guarantee is valid in private homes for 5 years from the purchase date Proof of purchase has to be provided when making a guarantee claim By use in commercial or institutional applications the guaran...

Page 10: ...ts are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti Copying in Design LEFROY BROOKS INC 1828 TROUTMAN STREET RIDGEWOOD NY 11385 TELEPHONE 718 302 5292 FAX 718 302 4177 COPYRIGHT LBIP LTD 2013 718 302 5292 www lefroybrooks com ...