6
Technical data
2.2
Ratings
120VAC Doubler / 240VAC Models
Type
Power
[Hp/kW]
Mains
Output Current
SM2
Watts
Loss
SM4
Watt
Loss
Voltage
(1)
I
in
(120V)
I
in
(240V)
I
n
CLim
max
(2)
174603
0.33 / 0.25
120 V Single-phase (1/N/PE)
(90 … 132 V)
OR
240 V Single-phase (2/PE)
(170 … 264 V)
6.8
3.4
1.7
200
24
174604-
174652
0.5 / 0.37
9.2
4.6
2.4
200
32
32
174605-
174653
1 / 0.75
16.6
8.3
4.2
200
52
41
174651-
174654
1.5 / 1.1
20.0
10.0
6.0
200
74
74
240VAC Models
Type
Power
[Hp/kW]
Mains
Output Current
SM2
Watts
Loss
SM4
Watts
Loss
Voltage
(1)
I
in
1~ (2/PE)
I
in
3~ (3/PE)
I
n
CLim
max
(2)
174606
0.33 / 0.25
240 V Single Phase (2/PE)
3.4
-
1.7
200
20
174607-174655
0.5 / 0.37
240 V Single-phase (2/PE)
OR
240 V Three-phase (3/PE)
(170 … 264 V)
5.1
2.9
2.4
200
27
30
174608-174656
1 / 0.75
8.8
5.0
4.2
200
41
42
174609-174657
1.5 / 1.1
12.0
6.9
6.0
200
64
63
174610-174658
2 / 1.5
13.3
8.1
7.0
200
75
73
174611-174659
3 / 2.2
17.1
10.8
9.6
200
103
97
174612
1.5 / 1.1
240 V Three-phase (3/PE)
(170 V … 264 V)
-
6.9
6.0
200
64
59
174613
2 / 1.5
-
8.1
7.0
200
75
69
174614
3 / 2.2
-
10.8
9.6
200
103
93
174615-174660
5 / 4.0
-
18.6
16.5
200
154
139
174616-174661
7.5 / 5.5
-
26
23
200
225
167
174617-174662
10 / 7.5
-
33
29
200
274
242
174618
15 / 11
-
48
42
180
485
468
174619
20 / 15
-
59
54
180
614
591
(1) Frequency Range: 48 Hz … 62 Hz
(2) Current Limit (CLim) is a percentage of the output current, I
n
. CLim
max
is the maximum setting for P171.