5.9 Parameter Number Definitions (8 bit)
Central Scene( press central button )
0x00(press 1 time)
0x01
0x01(release)
0x01
0x02(held)
0x01
0x03(press 2 times)
0x01
Parameter
Number
Description
Default
Value(dec
)
Size
0x01
7210Range
Set the range about magnetic field
Range:
0-the range of parameter 0x02 is 0x00000001-0x00004B00, the range of parameter
0x03 is 0x00000001-0x00002300.
1- the range of parameter 0x02 is 0x00000001-0x0002EE00, the range of parameter
0x03 is 0x00000001-0x00015E00.
0
1
0x02
7210OP
Set the average magnetic field in ut
Range:
0x00000001-0x00004B00 or
0x00000001-0x0002EE00
640
4
0x03
7210PolHyst
Set the offset about magnetic field
Range:
0x00000001-0x00002300 or
0x00000001-0x00015E00
200
4
0x0A
LowBatPrecent
This parameter defines a battery level as the “low battery”.
Range:
0x05-0x32
10
1
0x0E
BasicEnable
Enable/Disable BASIC SET command
0 – Disable.
1 – Enable.
0
1
0x0F
BasicReverse
Door Sensor reverse its value of BASIC SET when the magnet is triggered.
0 -Send BASIC SET VALUE = 0xFF/0x00 to nodes associated with group 2 when door
is opened/closed.
1 –Send BASIC SET VALUE = 0/255 to nodes associated with group 2 when door is
opened/closed.
0
1
0x20
Bypass
Enable/Disable Bypass mode
0 – Enable.
1 – Disable.
0
1