9.3.8 Version Report Commands

 

Parameter 

Value (HEX) 

Z-Wave Protocol Library Type 

0x03 

Z-Wave Protocol Version 

0x04 

Z-Wave Protocol Sub Version 

0x34 

Firmware 0 Version 

Firmware Version Upper 8 bits 

Firmware 0 Sub Version 

Firmware Version Lower 8 bits 

Hardware Version 

0x01 

Number of firmware targets 

0x00 

 

9.3.9 Basic Commands

 

There is no relevant commands are available for mapping. Sensor will send “Basic Set” via the lifeline group.

 

9.3.10 Configuration Command Parameters

 

Door/Window Sensor offers a wide variety of advanced configuration settings. Below parameters can be 
accessed from 

the 

main controller

s configuration interface. 

Parameter 

 

 

Number 

of 

Bytes 

Default 
Value 

Function Description 

10 (0x0A) 

 

 

10 

Low Battery Power Level of alarm 
threshold  values:  the  value  range 
are  10~50  for  percentage,  so  the 
Battery  Low  Power  level  can 
setting 10%~50%. 

254 (0xFE) 

 

 

Configuration Lock function: when 
it  was  lock  then  the  other 
parameters  value  cannot  change 
unless this parameter. 
0= unlock 
1= lock 

255* 
(0xFF) 
 

 

 

NA 

Value=0x8888888, Default=1, 
Size=4 
Reset to factory configuration and 

removed the Z-wave network. 

 

 

NA 

Value=0x88000000, Default=1, 
Size=4 
Reset Configuration parameter to 
default value. 

 
Note: Parameter 0xFF is a set-only parameter.

 

Summary of Contents for 7A-SS-VE-H0

Page 1: ...nsor Content Contact Sensor 2 1 Product Introduction 2 2 Product Appearance 2 3 Specification 3 4 Features Capabilities 3 5 Installation Position and Notes 4 6 Product Installation 4 7 Product Usage 5 8 Attention 6 9 Z Wave Command 7 ...

Page 2: ... for the product s firmware upgrade If you want your Door Window Sensor to be a security device that uses secure encrypted messages to communicate in a Z Wave network then a security enabled Z Wave controller gateway is needed 2 Product Appearance Product main components and function overview Reset Hold the key for 5s to reset the sensor After reset Door Window Sensor will send Device_Reset_Locall...

Page 3: ... H for Magnetic Part 4 Features Capabilities 1 The LEEDARSON Door Window Sensor contains a sensor body and a magnet 2 The LEEDARSON Door Window Sensor detects through the separation and combination of the main body and the magnet 3 Recommend installation distance between the sensor body and the magnet is 10MM 4 The Sensor also anti tamper functionality Once the sensor is moved it will notify the g...

Page 4: ...ould not be mounted on a metal frame 6 Product Installation This product can be mounted by screws or 3M adhesive tape Install it according to the diagram below Push the bracket upwards to separate it from the body then fix the bracket on the door window by screw or 3M tape Take off the bracket on the back install battery into the body The LED will slowly flash 3 times Be careful when installing th...

Page 5: ...ED will blink 3 times Otherwise the LED will blink for 3 seconds and then turn off in which case you will need to repeat the process from step 2 7 3 How to reset a Door Window Sensor Reset procedure deletes memory including all information on the Z Wave network and the hub Contact Sensor s Reset Procedure 1 Make sure the sensor is powered 2 Press and hold the button for 5 seconds 3 Release the but...

Page 6: ... is in low status the detector will give out low battery signal to controller 8 Attention 1 If the sensor needs to be cleaned remove power and use a soft cloth with a little alcohol and wipe down the device 2 This product is just for indoor use only 3 Replace the battery immediately when the low battery warning is indicated ...

Page 7: ... COMMAND_CLASS_BATTERY V1 COMMAND_CLASS_WAKE_UP V2 COMMAND_CLASS_POWERLEVEL V1 COMMAND_CLASS_CONFIGURATION V1 COMMAND_CLASS_FIRMWARE_UPDATE_MD V2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 Security device The node info frame supports COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_MANUFACTURER_SPECIF IC V2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_DEVICE_R...

Page 8: ...rt Sensor will send Notification Report when the sensor body and magnet removed or combined 2 Battery Report Sensor will send Battery Report when the battery level is low and the battery report s value is 0xFF 9 3 3 Association Group Info Command A Association Group Name Command Report Team No Value 1 St The ASSIC of Lifeline 4C 69 66 65 6C 69 6E 65 B Association Group Info Command Report Paramete...

Page 9: ...ake Up Interval Step Seconds 60 seconds 9 3 5 Battery Command A If the Controller or Gateway sends the Battery Get command to the Door Window Sensor then Door Window Sensor will report the Battery Power Level to the Controller or Gateway If the Battery Voltage 3 0V the Battery Power Level is 100 If the Battery Voltage 2 3V the Battery Power Level is 0 B If the Battery has a low voltage of 10 or le...

Page 10: ... of advanced configuration settings Below parameters can be accessed from the main controller s configuration interface Parameter Number of Bytes Default Value Function Description 10 0x0A 1 10 Low Battery Power Level of alarm threshold values the value range are 10 50 for percentage so the Battery Low Power level can setting 10 50 254 0xFE 1 0 Configuration Lock function when it was lock then the...

Page 11: ... ...

Reviews: