7
LeeBoy Model 8510B Conveyor Paver
7-15
Maintenance
Conveyor Limit Switch
Adjustment
In order for the conveyor’s start and stop to occur at the
correct position, small adjustments may be necessary
to the micro-switch
located on the
conveyor flap
. There are two positions
of the conveyor flap: one upper, shutting the conveyor
OFF, and one lower, turning the conveyor ON. Read the
following procedures carefully, referring to the figures
as needed.
1. Raise the conveyor flap
6-1/2 to 7
in. (16.5 to 17.8 cm) from bottom of the tank mount
support
. Secure conveyor flap so
Conveyor Micro-Switch Location
Figure 7-12
it remains in this position. If micro-switch clicked
OFF within the 6 1/2 to 7 in. (16.5 to 17.8 cm) limit, no
further adjustment is required to the upper travel.
2. If the micro-switch
did not click OFF,
adjustment is needed. Remove the linkage
attaching the actuator arm
to the eyelet on the flap pivot housing
.
3. Loosen setscrew “A”
, on the
actuator arm
. Reposition this arm
by either rotating it clockwise or counterclockwise
depending where the micro-switch clicked OFF
during the conveyor flaps upward travel (see
).
1 - Microswitch
2 - Conveyor Flap
3 - Tank Mount Support
4 - Linkage
5 - Actuator Arm
6 - Flap Pivot Housing
Return to
Last Viewed
Summary of Contents for 8510b
Page 1: ...Operations Service And Parts Manual LeeBoy Model 8510B Conveyor Paver Manual No 1003096 02...
Page 2: ......
Page 22: ...NOTES LeeBoy Model 8510B Conveyor Paver 2 8 Safety Return to Last Viewed Return to Thumb Index...
Page 134: ...NOTES LeeBoy Model 8510B Conveyor Paver 9 2 Schematics Return to Last Viewed Return to 9...