Notice:  

• Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable’s shield 

conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer 

casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special Note: Line termination:

      • When longer runs of cable are used, you may need to use a terminator on the last unit to 

        avoid erratic behaviour.

Using a cable terminator (part number CABL90) will decrease the possibilities of erratic 

behaviour. 

5-Pin XLR DMX Connectors:

     • Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin 

       XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin 

       XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the 

       correct cable conversion.

Termination reduces signal transmission problems 
and interferance. it is always advisable to connect a 
DMX terminal, (resistance 120 Ohm 1/4 W) between 
pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.

 LEDJ MATRIX STARCLOTHS   

 

 

 

                                     DMX SET UP

Summary of Contents for STAR15

Page 1: ...LEDJ Pro 3 x 2M Matrix Tri LED Cloth STAR16 LEDJ 3 x 2M Matrix Tri LED Cloth STAR15 USER MANUAL www prolight co uk...

Page 2: ...your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good worki...

Page 3: ...ment is dropped or damaged disconnect the mains power supply imme diately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperatur...

Page 4: ...r LEDs STAR16 Hanging tabs on 3 sides Fire retardent material Power consumption 60W STAR15 130W STAR16 Power supply 240V Dimensions 3000 x 2000mm 3 x 2M Weight 8 5Kgs STAR15 11 0Kgs STAR16 Overview LE...

Page 5: ...omising or creating a show In this mode you will be able to control each individual trait of the cloth and each cloth independently The Matrix Cloths uses 2 channels of control Use dip switches 1 9 to...

Page 6: ...e controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a dat...

Page 7: ...le terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin...

Page 8: ...LEDJ MATRIX STARCLOTHS DIP SWITCH REFERENCE CHART DMX Dip Switch Quick Reference Chart Dip Switch Position...

Reviews: