background image

www.prolight.co.uk

100W UV COB Flood

  

User Manual

5

Operating instructions

MENU

S L A u

Slave mode

d o n

d o n

d o F F

Display backlight

S t n d

rE

v

Display inverse

d E F A

Reset factory settings

S J - 1

S J - 8

Sound active/
sound sensitivity

S J - 5

U. 0 0 0

U. 2 5 5

F 5. 0 0

F 5. 1 5

Manual dimming 
mode

U. 2 5 5

d. 0 0 1

d. 5 1 2

C h 0 1

C h 0 2

DMX address/
channel setting

d. 0 0 1

Summary of Contents for LEDJ187

Page 1: ...Order code LEDJ187 100W UV COB Flood User Manual...

Page 2: ...in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is...

Page 3: ...ightclubs bowling centres and skating rinks 100W UV COB Flood 257mm 245mm 310mm 1 x 100W UV COB LED Beam angle 80 native 25 40 and 50 beam reduction lenses supplied Ultra violet wavelength 400nm 1 1kH...

Page 4: ...ON output 09 Fuse T2A 250V 10 Hanging bracket 11 Hanging bracket adjustable knob In the box 1 x fixture 1 x 25 beam reduction lens 1 x 40 beam reduction lens 1 x 50 beam reduction lens 1 x power cable...

Page 5: ...Slave mode d o n d o n d o F F Display backlight S t n d r E v Display inverse d E F A Reset factory settings S J 1 S J 8 Sound active sound sensitivity S J 5 U 0 0 0 U 2 5 5 F 5 0 0 F 5 1 5 Manual di...

Page 6: ...des To set the other units in slave mode press the MENU button on the rear of the unit to show SLAu on the LED display and press the ENTER button to con firm the setting The units will now run in sequ...

Page 7: ...on doff display backlight off Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Display inverse To access the display inverse setting press t...

Page 8: ...DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ens...

Page 9: ...pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin X...

Page 10: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Page 11: ...www prolight co uk 100W UV COB Flood User Manual 11...

Page 12: ...www prolight co uk 100W UV COB Flood User Manual 12...

Reviews: