Colour change mode:

To access colour change mode press 

“MENU”

 until the display shows  

JUNP

 on the LED display.  

Press 

“ENTER” 

to and use the 

“UP”

 and 

“DOWN”

 buttons to adjust the speed between  

J500

 ~ 

J599

. Press 

“ENTER” 

to and use the 

“UP”

 and 

“DOWN”

 buttons to adjust the flash  

speed between  

JF00

 ~ 

JF99

. Press the 

“ENTER” 

button to confirm the setting.

Value: 0 - 99 (0 = slow speed, 99 = fast speed)

 

To exit out of any of the above options, press the 

“MENU”

 button.

Operating instructions

9 channel mode:

Channel Value

Function

1

000-255 Master dimmer (0-100%)

2

000-009 No function
010-255 Strobe (slow-fast)

3

000-255 Red (0-100%)

4

000-255 Green (0-100%)

5

000-255 Blue (0-100%)

6

000-255 White (0-100%)

7

000-255 Amber (0-100%)

8

000-255 UV (0-100%)

9

000-005 Blackout
006-010 Red
011-015 Green
016-020 Blue
021-025 White
026-030 Amber
031-035 UV
036-040 Yellow (R: 255, G: 200, A: 255)
041-045 Cyan (G: 255, B: 255)
046-050 Lavender (R: 170, B: 210)
051-055 Bright green (G: 255, A: 180)
056-060 Magenta (R: 255, B: 90, UV: 255)
061-065 Turquoise (G: 255, B: 180, UV: 255)
066-070 Orange (R: 200, A: 200)
071-075 Cool white (R: 70, G: 190, B: 255, A: 200)
076-080 Warm white (R: 230, G: 255, B: 255, A: 255, W: 255)
081-170 Colour change (slow-fast)
171-255 Colour fade (slow-fast)

Summary of Contents for HEX Par 7

Page 1: ...Order code LEDJ228 HEX Par 7 Exterior Fixture User Manual...

Page 2: ...ent and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable...

Page 3: ...7 Power consumption 70W Power supply 100 240V 50 60Hz Dimensions 280 x 245 x 150mm Weight 3 8kg Order code LEDJ228 245mm 150mm 280mm IP65 01 Hanging bracket 02 Hanging bracket adjustment knobs 03 LED...

Page 4: ...NTER r 0 0 0 ENTER UP DOWN g 0 0 0 g 2 5 5 ENTER UP DOWN b 0 0 0 b 2 5 5 ENTER UP DOWN U 0 0 0 U 2 5 5 ENTER UP DOWN y 0 0 0 y 2 5 5 ENTER UP DOWN P 0 0 0 P 2 5 5 ENTER UP DOWN C F 0 0 C F 9 9 u e r S...

Page 5: ...and each fixture independently To access the DMX channel mode press the MENU button on the rear of the unit to show Chnd on the LED display Now press the ENTER button and use the UP and DOWN buttons t...

Page 6: ...te R 230 G 255 B 255 A 255 W 255 081 170 Colour change slow fast 171 255 Colour fade slow fast 3 channel mode 2 Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4...

Page 7: ...el mode Channel Value Function 1 000 255 Master dimmer 0 100 2 000 009 No function 010 255 Strobe slow fast 3 000 255 Red 0 100 4 000 255 Green 0 100 5 000 255 Blue 0 100 6 000 255 White 0 100 7 000 2...

Page 8: ...d use the UP and DOWN buttons to choose the static colour between St01 St15 Press ENTER to and use the UP and DOWN buttons to adjust the flash speed between SF00 SF99 Press the ENTER button to confirm...

Page 9: ...y timeout Display timeout allows the user to choose after what period of time the display goes off To change the display timeout press MENU until the display shows dISP on the LED display Press ENTER...

Page 10: ...s and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a...

Page 11: ...XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR c...

Page 12: ...ble harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material res...

Reviews: