Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 

 

 

 

DMX setup

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:

LEDJ 1m Interior - 
Exterior DMX cable

LEDJ 1m Exterior  
DMX cable

LEDJ 2m Exterior  
DMX cable

LEDJ 5m Exterior  
DMX cable

LEDJ 10m Exterior  
DMX cable

Order code: LEDJ91

Order code: LEDJ141 Order code: LEDJ142 Order code: LEDJ143 Order code: LEDJ144

LEDJ 1m Exterior  
Power cable

LEDJ 2m Exterior  
Power cable

LEDJ 5m Exterior  
Power cable

LEDJ 10m Exterior  
Power cable

Order code: LEDJ146 Order code: LEDJ147 Order code: LEDJ148 Order code: LEDJ149

Also remember 
that DMX cable 
must be daisy 
chained and 
cannot be split.

Summary of Contents for HEX Par 7

Page 1: ...Order code LEDJ228 HEX Par 7 Exterior Fixture User Manual...

Page 2: ...ent and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable...

Page 3: ...7 Power consumption 70W Power supply 100 240V 50 60Hz Dimensions 280 x 245 x 150mm Weight 3 8kg Order code LEDJ228 245mm 150mm 280mm IP65 01 Hanging bracket 02 Hanging bracket adjustment knobs 03 LED...

Page 4: ...NTER r 0 0 0 ENTER UP DOWN g 0 0 0 g 2 5 5 ENTER UP DOWN b 0 0 0 b 2 5 5 ENTER UP DOWN U 0 0 0 U 2 5 5 ENTER UP DOWN y 0 0 0 y 2 5 5 ENTER UP DOWN P 0 0 0 P 2 5 5 ENTER UP DOWN C F 0 0 C F 9 9 u e r S...

Page 5: ...and each fixture independently To access the DMX channel mode press the MENU button on the rear of the unit to show Chnd on the LED display Now press the ENTER button and use the UP and DOWN buttons t...

Page 6: ...te R 230 G 255 B 255 A 255 W 255 081 170 Colour change slow fast 171 255 Colour fade slow fast 3 channel mode 2 Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4...

Page 7: ...el mode Channel Value Function 1 000 255 Master dimmer 0 100 2 000 009 No function 010 255 Strobe slow fast 3 000 255 Red 0 100 4 000 255 Green 0 100 5 000 255 Blue 0 100 6 000 255 White 0 100 7 000 2...

Page 8: ...d use the UP and DOWN buttons to choose the static colour between St01 St15 Press ENTER to and use the UP and DOWN buttons to adjust the flash speed between SF00 SF99 Press the ENTER button to confirm...

Page 9: ...y timeout Display timeout allows the user to choose after what period of time the display goes off To change the display timeout press MENU until the display shows dISP on the LED display Press ENTER...

Page 10: ...s and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a...

Page 11: ...XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR c...

Page 12: ...ble harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material res...

Reviews: