background image

 

2 INSTALLATION 

2.1MOUNTING 

UPRIGHT

.......

 

 

For overhead use, always install a safety cable that can hold at least 10 times the weight of 
the fixture. 

 

For overhead installation, the fixture must be always secured with a safety wire that can bear 
at least 10 times the weight of the fixture

Secure the fixture with a safety cable through the 

rear safety eye as shown. 

 

Ensure that the structure (truss) to which you are attaching the fixture is secure 

 

 

Hanging layout 

 

2.2 POWER CONNECTIONS 

 

POWER Linking: 3 units@110V

6 units@220V. 

 

This product has an auto-ranging power supply that can work with an input voltage range of 
100–240 VAC, 50/60 Hz. 

AC Plug 

Connection 

Wire (U.S. 

Wire(Europe) 

Screw Color 

AC Live 

Black 

Brown 

Yellow/Brass 

AC Neutral 

White 

Blue 

Silver 

AC Ground 

Green/Yellow 

Green/Yellow 

Green 

 

Summary of Contents for XPRESSION 250RGBLA

Page 1: ...USER MANUAL...

Page 2: ...1 1 PRODUCT 1 1 TECHNICAL SPECIFICATIONS LED colors RGBAL 200W LED Power 240W Voltage Range AC100 240V 50 60Hz Protection IP20 Operation Temperature 0 45 Dimensions 510X285X261mm Weight 7 6kg...

Page 3: ...e fixture on and off in short intervals as this would reduce the lamp s life Do not touch the device s housing bare hands during its operation housing becomes hot The surface of the product s casing c...

Page 4: ...fixture with a safety cable through the rear safety eye as shown Ensure that the structure truss to which you are attaching the fixture is secure Hanging layout 2 2 POWER CONNECTIONS POWER Linking 3 u...

Page 5: ...2 data link is required in order to control the fixture via DMX The fixture has 3 5 pin XLR connectors for DMX data input and output Each unit has 13 DMX channels so the DMX Addresses should increase...

Page 6: ...5Hz GREEN 0 255 BLUE 0 255 AMBER 0 255 LIME 0 255 ZOOM 0 255 STROBE 0 25 ADDRESS 001 512 default001 Set the DMX ADDRESS RUN MODE DMX default DMX Using the DMX 512 controller to control SLAVE Master Sl...

Page 7: ...n of fan all power STUDIO Automatic rotation of fan DISP KEY ON default Locks display passcode is UP DOWN UP DOWN ENTER OFF DISP TIME ON Display backlight always on 10s Turns off display backlight aft...

Page 8: ...00K 55 3000K 70 3200K 85 4000K 100 4500K 115 5000K 130 5600K 145 6000K 160 6500K 175 7000K 190 8000K 205 10000K 255 10000K CH 6 STROBE 0 9 NO FUNCTION 10 99 STROBE FROM SLOD TO FAST 0 25Hz 100 109 NO...

Page 9: ...RESET 221 230 RESERVED 231 240 RESERVED 241 255 RESERVED SSP 9CH TOUR 13CH TR16 19CH Value Function CH 1 CH 1 CH 1 0 255 MASTER DIMMER CH 2 0 255 MASTER DIMMER FINE CH 2 CH 2 CH 3 0 255 RED CH 4 0 25...

Page 10: ...CH 15 STROBE 0 9 NO FUNCTION 10 99 STROBE FROM SLOD TO FAST 0 25Hz 100 109 NO FUNCTION 110 179 THUNDER STROBE 180 189 NO FUNCTION 190 255 RANDOM SROBE CH 8 CH 10 CH 16 0 255 ZOOM CH 11 CH 17 AUTO 0 40...

Page 11: ...031 040 RESERVED 041 050 RESERVED 051 060 RESERVED 061 070 LIVE 071 080 STUDIO 081 090 POWER 091 100 RESERVED 101 110 DIMMER OFF 111 120 DIMMER DIM4 121 130 RESERVED 131 140 RESERVED 141 150 RESERVED...

Page 12: ...6 COLOR 23 121 125 R94 Kelly Green 0 185 0 459 COLOR 24 126 130 L327 Forest Green 0 162 0 496 COLOR 25 131 135 L191 Cosmetic Aqua Blue 0 3 0 318 COLOR 26 136 140 L728 Steel Green 0 256 0 302 COLOR 27...