SECTION 2:TROUBLESHOOTING THE HEAT SYSTEM
When troubleshooting the heat system,problems usually fall
under two descriptions;A)no heat or B) uncontrolable,
runaway heat.
A.NO HEAT
1)
Basic.
Check the power cord.Make sure it is securely
inserted in the wall outlet(110 vac)and the receptacle
located on the back of the laminator.
Be sure to engage the heat switch to the up or “l”
position as denoted by the label markings next to the
switch.The switch will illuminate red when engaged,and the
digital display should light up and read the actual present
temperature indicating power is getting to the system.If the
heat switch does not light up(and concurrently neither would
the digital display),disconnect the power cord and with a
phillips head screw driver remove the 11 screws from the
right hand plastic housing,remove the cam shaft handle
using a 1/8” allen wrench and with a small straight blade
screwdriver remove the speed control knob.Then remove
the housing and inspect all the wiring and connectors for
any that may be loose or disconnected.Carefully reconnect
any loose or disconnected wires exactly as shown in the
schematics in the back of the owners/operation manual.If
any wires are broken or shorted out,call your dealer,a
servicing dealer/technician,the Ledco service dept, or move
on to the next,intermediate level of troubleshooting.
If the wiring looks good upon initial visual inspection and
the heat switch and digital display still do not illuminate upon
engaging the heat switch,now examine the 1.5 amp fuse