11
forward position.It should turn the drive motor on.If
not,disconnect the power cord and using a small straight
blade screwdriver,gently pop out the spring loaded fuse
holder and fuse from the rear of the machine next to the
power cord receptacle.Visually examine the ¾ amp fuse to
see if the fuse has failed.If the fuse has failed it will look
discolored and the element inside broken.Replace with a
new 3/4 amp fuse(
always
replace fuses with
exactly
the
same rated fuse).The drive system should now be
operational.
If the drive motor sounds like it is operational and there is
still no drive (make sure the rubber rollers are in the down,
engaged position using the cam shaft knob),disconnect the
power the cord and remove the left hand plastic housing in
the same manner as the right side as described in the
previous section.Visually check the drive chain to make sure
it is secure.If the chain is not connected,reconnect the chain
at the connecting link.If the connecting link is missing or
damaged,call your dealer or Ledco for a replacement link
(part # PRC 084),reconnect and re-install the chain,and the
drive system should be operational.
Next,move on to visually checking all sprockets to make
sure they are tight to their respective shafts.If loose,use a
1/8” allen wrench to tighten the set screws in the sprockets,
making sure the set screw tightens on the flat surface of its
respective shaft.Also be sure the sprockets are positioned
for proper chain alignment(13/16” from the side panel to the
center of the chain.)With the chain properly connected and
the spockets securely tightened to their shafts,the drive
system should now be operational.If not,you should now
consult with your dealer,a sevicing dealer/technician,the