Reference Manual
Rio Rancho, NM
25
Firmware Updates
Using the Update Wizard
The control panel can be used to download firmware
updates to the DM units. The Update Wizard guides you
through the steps of the update process. Since a failed
firmware update can leave the DM in an unusable state,
it is important to follow the instructions in the Update
Wizard exactly. This procedure uses a DM1624F; how-
ever, it applies to all units in the DM series.
NOTE: The update process is possible
only
using
a USB connection.
Firmware updates are distributed as a file whose name
follows the pattern “DM1624F-vX_X_X.update”, where
the “X_X_X” is a placeholder for a firmware version
number. For example a firmware update for version
number “1.1.12” would have the filename “DM1624F-
v1_1_12.update”. The dots normally used to separate
the three parts of the version number are replaced with
underscores in the filename for clarity.
Before starting make sure that the proper update file is
on hand. Connect the DM1624F to a computer sys-
tem with a USB cable. Apply power to the DM1624F
and start the control panel software on the computer
system.
1.
Choose
File->Update...
from the Control Panel
Menu Bar to open the
Update DM1624F Firmware
Wizard
.
2.
The first page of the Wizard displays instructions
for the process of forcing the DM1624F into update
mode. Follow them carefully and then click
Next
to
move to the
SELECT DEVICE FOR UPDATE
.
3.
Any LecNet2 device detected on the USB port will
be listed. Click the DM unit to be updated. If nothing
appears on the list, or the unit to be updated does
not appear, check that the USB cable is connected
and click
Refresh List
.
Once the DM1624F is selected, click
Next
to move
to
SELECT UPDATE FILE
.
Summary of Contents for DM812
Page 2: ...DM Series Digital Matrix Processors LECTROSONICS INC 2 ...