Reference Manual
Rio Rancho, NM
21
Use the Item Select Buttons to enter the existing pass-
code. Symbols will appear in the upper right section of
the screen to confirm button presses as you enter the
passcode. Press the PRESS FOR MENU/SELECT
control to accept the old passcode. If the passcode
is not correct, an “Invalid” error message will appear
briefly on the screen.
Passcode Item Select Button
confirmation
Item Select Buttons
When the existing passcode has been accepted, the
“Old” screen will be replaced by the “New:” screen.
Use the Item Select Buttons to enter the new four digit
passcode. Like before, symbols will appear in the up-
per right section of the screen to confirm button presses
as you enter the new passcode.
Passcode Item Select Button
confirmation
Item Select Buttons
NOTE: The passcode must always include four
button presses
Restoring the default passcode
To restore the passcode to the factory default setting,
press and hold Item Select Buttons 2 and 5 in while
powering up the power. Hold the buttons through the
entire Boot Sequence. The passcode will be reset to
the factory default: 1, 2, 3, 4.
NOTE: Hold in buttons 2 and 5 while powering up
to restore the factory default passcode: 1, 2, 3, 4
PUSH FOR
MENU/SELECT
BACK
Button 2
Button 5
Item Select Buttons
Command View Screen
The Command View Screen is a convenient utility to
assist in verifying correct serial commands have been
sent from an external device, such as a computer
system, to the unit. This screen is used primarily for
diagnostics when setting up or troubleshooting serial
remote control systems.
⇓
Navigate to the TopMenu and use the PUSH FOR
MENU/SELECT control to highlight CmdView.
The Command View Screen displays a rolling list of the
serial commands as they arrive in the unit. Each com-
mand that is received will appear on a separate line in
the screen.
Serial Port Speed Adjustment
The Serial Port Screen is used to set the baud rate for
the units RS-232 serial input port.
Navigate to the TopMenu, then rotate the PUSH FOR
MENU/SELECT control to highlight SerPort. Press the
control to access the Serial Port Setup Screen.
⇓
Items List
Parameter
Display Area
Screen Title