19
end of life before the battery stops working. The best
way to monitor rechargeable batteries is to run a test
to determine how long it will run the transmitter, then
use the timer to assess the remaining time.
STEP SIZE sets the increments for fre-
quency adjustment at 100 or 25 kHz.
RX MENU
TOP MENU links back to the Top Menu for
overall system setup.
FREQ ADJUST opens a setup screen to
manually select the frequency of each
receiver module.
NOTE: The setting for 100 or 25 kHz frequency
increments is in the TX Menu under STEP SIZE,
selectable on a per channel basis.
AUDIO LEVEL is used to adjust the output
level of each receiver. The built-in tone
generator is also enabled in this screen.
SMART NR sets the desired noise reduc-
tion mode for each channel: NORMAL,
FULL or OFF.
PHASE sets the polarity (phase) of each
output to the desired value: NORMAL or
INVERTED.
RX LINK (DIVERSITY LINK) selects
adjacent receivers to be paired for Ratio
Diversity operation, or to be operated
individually with Antenna Phase Switching
Diversity.
COMPAT MODE sets the DSP-based
compatibility mode for each channel.
NOTE: If your Lectrosonics Transmitter is
set to Nu Hybrid Compatibility Mode, set
the receiver to Euro Digital Hybrid Wireless
®
(EU
HYBR). Make certain the COMPAT mode is set
to match the mode in the transmitter for optimum
audio quality.
SMART NR
PHASE
RX LINK
SPECTRUM
SCAN
LOCK PANEL
BACK LIGHT
COMPAT MODE
ANTENNA
POWER
NETWORK
SETUP
RS232 SETUP
COMMAND
VIEW
SYSTEM INFO
BATT TIMER
MODULE
POWER
TALKBACK
GROUP
TUNING
SQUELCH BP
STEP SIZE