background image

 

 

Key Features 

 

The 

Control Panel Display 

provides a 

series of control buttons for 

OUTPUT 

level, 

 

 

OUTPUT 

P o o l  

P i l o t ™   

S o f t   T o u c h   

BOOST 

mode and 

SETUP 

functions, with 

 

FLOW-OK 

SERVICE 

CELL POWER 

diagnostic indicator lights for 

FLOW-OK

1

00% 

 

SALT and SERVICE. 

Two additional 

 

indicator lights show the selected setup 

CELL POWER 

and 

REVERSING 

cycle. 

 

50% 

SALT 

OK 

REVERSING 

The LECTRANATOR SOFT TOUCH MODEL 

 

BOOST 

SHORT 

L

OW 

NORMAL 

ST 60 SANITIZER 

OUTPUT 

level is adjustable from 

 

LONG 

0% (OFF) to 100 %(MAX). Press the 

Up/Down Arrow 

to set the desired output level. Little adjustment 

0% 

ADD 

Concealed Set Up Button 

is needed once the initial setting is established. 
The selected output level will remain steady when the system is at rest and will begin pulsing when the system is producing t he 
SANITIZING agent. 

Note: The 

LECTRANATOR SOFT TOUCH MODE

L ST 60 does not test for SANITIZER levels nor automatically 

adjust to maintain a desired SANITIZER level. This is done by periodically testing the water and adjusting the output levels up or 
down, as needed. 

The LECTRANATOR SOFT TOUCH MODEL ST 60 is designed with an 

AUTOMATIC TEMPERATURE COMPENSATION feature

which automatically adjusts the output level setting based upon changes in seasonal water temperatures only. This unique feature conveniently 
compensates for warm (more SANITIZER needed) or cold (less SANITIZER needed) water conditions. 
The 

SETUP Mode 

allows the user to program the 

CELL POWER 

and 

REVERSING 

cycle. To enter Setup Mode, press and hold 

the concealed Setup button (small bubble adjacent to the Salt OK light) until the 

CELL POWER 

light begins flashing. The 

LECTRANATOR 

SOFT TOUCH MODEL ST 60 

is set on 

“ 2 “ 

from the factory. Use the Up/Down Arrows to change the Cell Power setting if needed. Adjust 

the OUTPUT level at the new setting to maintain proper sanitizer levels. 

WARNING: 

Operating on 

“ 1 “ 

reduces cell power but extends cell life; 

“ 3 “ 

increases cell power but reduces cell life. 

Pressing the Setup Button once more will go to the 

REVERSING 

cycle. The LECTRANATOR SOFT TOUCH MODEL ST 60 is set on 

NORMAL

” from the factory for ideal cell life. Use the Up/Down Arrows to select the Reversing cycle. For conditions such as extremely high 

calcium levels or conditions that can cause the cell to scale quicker than the self-cleaning cycle can control, change the setting to “

SHORT

”. 

For optimum water chemistry balance according to the Saturation Index, see page 9, you can change the REVERSING cycle to 

LONG

”. Pressing the setup button once more will leave the Setup Mode and save the programmed Cell Power and Reversing 

settings.  Test your water chemistry parameters monthly and compare to the Saturation Index. 

WARNING

: Changing the Reversing cycle to SHORT will also reduce cell life. However, operating the cell under scaled conditions 

on “Normal” or “Long” is more detrimental to the life of the cell and changing the Reverse cycle is suggested. 

The 

BOOST Button 

activates the Boost light when it is pressed once. This light indicates that the system is in Boost Mode and will 

produce the SANITIZING agent for 24 hours.  The SANITIZING agent can be produced for 72-hours by pressing and holding the 
BOOST button for 5-seconds from the Boost-Off position. This is called the 

Super-Boost Mode

.  A flashing Boost light indicates 

that the system has successfully entered this mode. In either mode, the SANITIZING agent is produced continuously, throughout the 
normal On/Off cycles of the pump and throughout all power line disturbances at an output SANITIZING level of 100% regardless of 
the normal SANITIZINGoutput level setting. The system will discontinue operation of the Boost mode or Super Boost mode if the 
boost button is pressed once more and return to the normal SANITIZING output level setting. The pool/spa pump must be turned on 
during the whole boost cycle.  Do not let the pump run on a timer during that period. 

The 

SALT 

light indicates the salt level in the water. The salt level should be maintained between 2.8 – 3.2 g/l (2800 – 3200 ppm). 

The SALT-

OK 

light will be on if this salt level is achieved. If the salt level drops below 2.5 g/l (2500 ppm), the SALT-

LOW 

light 

will turn on and the system will continue to produce the SANITIZING agent. If the salt level drops below a safe value, the SALT- 

ADD 

light will turn on and the system will no longer continue to produce the SANITIZING agent. 

(

NOTE 

Maintaining high salt levels above recommended range can contribute to corrosion of pool/spa equipment. Salt levels 

exceeding the recommended concentration can be reduced by diluting the pool/spa with fresh water.) See Appendix (page 14) to 
determine your salt level. 

The 

FLOW-OK 

light turns on when there is sufficient flow. Any problems with insufficient water flow is indicated by a Flow-OK 

light that is not on and a Flashing Service Light (single flash pattern). 

The 

SERVICE 

light flashes when service is needed. A Single flash pattern of the service light indicates insufficient water Flow. A 

Double flash pattern of the service light indicates high cell volts and low amps, which is caused by a scaled or failing cell  or a 
loose/defective cell cord. A Triple flash pattern o f the service light indicates high cell volts and low amps, which is caused by a failed 
power supply.  A Quadruple flash pattern of the service light indicates a failed tri-sensor or cord. 

Summary of Contents for ST 60

Page 1: ...n result in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATOR SYSTEMS INC 1034 72 Avenue N E Calgary Alberta T2E 8V9 Phone 1 866 517 7584 REGISTRATION NO 27840 PEST CONTROL PRODUCTS ACT LECTRANATOR SOFT TOUCH MODEL ST60 Chlorine or Bromine Generating One ST60 unit can treat a maximum of 1...

Page 2: ...T and Lectranator DigitalModel DIG60 REGISTRATION NUMBER 27843 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Read the Label and the Installation and Operation Manual of the chlorine or bromine generating device Lectranator Soft Touch Model ST60 or Lectranator Digital Model DIG 60 beforeusing Lectranator Systems Inc 1034 72 Ave N E Ca...

Page 3: ...cteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE C NSF50 IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the dir...

Page 4: ...Cell Model Number RC 13 LECTRANATOR SOFT TOUCH MODEL ST 60 by LECTRANATOR SYSTEMS INC Record The Following Information Factory Direct Customer Assistance HOTLINE 1 866 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet http www lectranator com Manufactured for Lectranator Systems Inc 2770 24 Avenue N E Calgary Alberta Canada T1Y 6V7 LECTRANATOR SOFT TOUCH MODEL ST 60 by LECTRAN...

Page 5: ...try in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product Children shouldnot use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your LECTRANATOR SOFT TOUCH MODEL ST 60 to connect a minimum 8 4 mm No 8 AWG in the U S A and ...

Page 6: ...ord and Tri Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b...

Page 7: ...er by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalentto0 77kg 1 68 lbs offreeavailable chlorine day 230 VAC 1 5AC amps RC 13CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum...

Page 8: ... located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre setfor connection to the LINE SIDEof your time clock electronic controller switch or relay to work in conjunction with your circulation pump Cell Cord Each Cell Cord contains...

Page 9: ...following this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf ...

Page 10: ...programmed Cell Power and Reversing settings Test your water chemistry parameters monthly and compare to the Saturation Index WARNING Changingthe Reversingcycle toSHORTwillalsoreduce celllife However operatingthecell underscaledconditions on Normal or Long is more detrimental to the life of the cell and changingthe Reverse cycle is suggested The BOOST Buttonactivates the Boost light when it is pre...

Page 11: ...m purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRSTwith the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Pool Volume in Liters US Gallons 3 780 1 000 9 430 2 500 18 900 5...

Page 12: ...anuric acid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL YourLECTRANATOR SOFT TOUCH MODEL ST 60 works most efficiently with salt levels between2 8 3 2g l 2800 3200 ppm If it falls be...

Page 13: ...tions remove these board removes with cover fuses and pump aux relay TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet activates a micro switch to verify proper flow The Salt sensor protects against lowsalt levels and the tempe...

Page 14: ...ixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution ina containerhighenough tocoverthe Cellblades You may also use TABEXLectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutralized ...

Page 15: ...olytic Cell Cell Unions and Cord ordered separately 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately DirectionalFlowIndicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt Sensor Blades Direct...

Page 16: ...ee Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calciumhardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to waterchemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Control B...

Page 17: ...n the case of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 Thesecondvalue is the watertemperaturein degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the next the un...

Page 18: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Reviews: