background image

 

 

****************************** 

 

This label transcript service is offered by the Pest Management Regulatory Agency to provide 
efficient searching for label information. This service and this information do not replace the 
official hard-copy label. The PMRA does not provide any guarantee or assurance that the 
information obtained through this service is accurate, current or correct, and is therefore not 
liable for any loss resulting, directly or indirectly, from reliance upon this service. 

Summary of Contents for ST 60

Page 1: ...n result in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATOR SYSTEMS INC 1034 72 Avenue N E Calgary Alberta T2E 8V9 Phone 1 866 517 7584 REGISTRATION NO 27840 PEST CONTROL PRODUCTS ACT LECTRANATOR SOFT TOUCH MODEL ST60 Chlorine or Bromine Generating One ST60 unit can treat a maximum of 1...

Page 2: ...T and Lectranator DigitalModel DIG60 REGISTRATION NUMBER 27843 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Read the Label and the Installation and Operation Manual of the chlorine or bromine generating device Lectranator Soft Touch Model ST60 or Lectranator Digital Model DIG 60 beforeusing Lectranator Systems Inc 1034 72 Ave N E Ca...

Page 3: ...cteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE C NSF50 IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the dir...

Page 4: ...Cell Model Number RC 13 LECTRANATOR SOFT TOUCH MODEL ST 60 by LECTRANATOR SYSTEMS INC Record The Following Information Factory Direct Customer Assistance HOTLINE 1 866 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet http www lectranator com Manufactured for Lectranator Systems Inc 2770 24 Avenue N E Calgary Alberta Canada T1Y 6V7 LECTRANATOR SOFT TOUCH MODEL ST 60 by LECTRAN...

Page 5: ...try in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product Children shouldnot use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your LECTRANATOR SOFT TOUCH MODEL ST 60 to connect a minimum 8 4 mm No 8 AWG in the U S A and ...

Page 6: ...ord and Tri Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b...

Page 7: ...er by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalentto0 77kg 1 68 lbs offreeavailable chlorine day 230 VAC 1 5AC amps RC 13CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum...

Page 8: ... located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre setfor connection to the LINE SIDEof your time clock electronic controller switch or relay to work in conjunction with your circulation pump Cell Cord Each Cell Cord contains...

Page 9: ...following this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf ...

Page 10: ...programmed Cell Power and Reversing settings Test your water chemistry parameters monthly and compare to the Saturation Index WARNING Changingthe Reversingcycle toSHORTwillalsoreduce celllife However operatingthecell underscaledconditions on Normal or Long is more detrimental to the life of the cell and changingthe Reverse cycle is suggested The BOOST Buttonactivates the Boost light when it is pre...

Page 11: ...m purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRSTwith the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Pool Volume in Liters US Gallons 3 780 1 000 9 430 2 500 18 900 5...

Page 12: ...anuric acid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL YourLECTRANATOR SOFT TOUCH MODEL ST 60 works most efficiently with salt levels between2 8 3 2g l 2800 3200 ppm If it falls be...

Page 13: ...tions remove these board removes with cover fuses and pump aux relay TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet activates a micro switch to verify proper flow The Salt sensor protects against lowsalt levels and the tempe...

Page 14: ...ixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution ina containerhighenough tocoverthe Cellblades You may also use TABEXLectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutralized ...

Page 15: ...olytic Cell Cell Unions and Cord ordered separately 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately DirectionalFlowIndicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt Sensor Blades Direct...

Page 16: ...ee Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calciumhardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to waterchemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Control B...

Page 17: ...n the case of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 Thesecondvalue is the watertemperaturein degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the next the un...

Page 18: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Reviews: