background image

 

CrossSync

 

User

 

Manual

21

CrossSync

 

Control

 

Panel

 

LeCroy

 

Corporation

Main Buttons

The

 

main

 

icons

 

are

 

explained

 

in

 

the

 

following

 

table.

TABLE 3.3:  Main Icons and Descriptions

Icons

Descriptions and Submenus

Open

 

File

The

 

Open

 

File

 

icon

 

opens

 

a

 

set

 

of

 

synchronized

 

traces

 

from

 

a

 

previous

 

session.

 

This

 

is

 

a

 

dual

mode

 

button;

 

clicking

 

on

 

the

 

down

 

arrow

 

displays

 

the

 

following

 

menu:

Zip

 

Most

 

Recent

 

Traces

Open

 

Traces

 

Folder

 

in

 

Windows

 

Explorer

Break

 

Sync.

 

Trace

 

Files

The

 

Break

 

Sync.

 

Trace

 

Files

 

icon

 

toggles

 

the

 

view

 

synchronization

 

between

 

traces.

Select

 

Application

The

 

Select

 

Application

 

icon

 

allows

 

you

 

to

 

select

 

the

 

application

 

suite

 

you

 

would

 

like

 

to

 

run.

 

This

 

is

 

a

 

dual

mode

 

button;

 

clicking

 

on

 

the

 

down

 

arrow

 

displays

 

the

 

following

 

menu:

FC

 

Protocol

 

Suite

PETracer

SAS

 

Protocol

 

Suite

SATA

 

Protocol

 

Suite

USB

 

Protocol

 

Suite

DDR

 

Protocol

 

Suite

IOTA

 

Protocol

 

Suite

Devices

The

 

Devices

 

icon

 

opens

 

the

 

Devices

 

dialog.

 

This

 

is

 

a

 

dual

mode

 

button;

 

clicking

 

on

 

the

 

down

 

arrow

 

displays

 

the

 

following

 

menu:

The

 

selected

 

Device

 

Name

 

and

 

Serial

 

Number

Refresh

Settings

The

 

Settings

 

icon

 

opens

 

the

 

LeCroy

 

CrossSync

 ‐ 

Settings

 

dialog.

 

There

 

are

 

four

 

tabs:

 

Applications,

 

Trace

 

File,

 

Time

 

Tune

 

and

 

General

 

where

 

the

 

application

 

settings

 

can

 

be

 

selected.

 

Record

The

 

Record

 

icon

 

starts

 

a

 

synchronized

 

session.

 

Summary of Contents for CrossSync

Page 1: ...CrossSync User Manual For LeCroy Protocol Analyzers CrossSync Control Panel Version 2 21 Document Version 1 12 August 2011 ...

Page 2: ...CTTO CHANGE WITHOUT NOTICE ALL INFORMATION EXAMPLES ANDRECOMMENDATIONS INTHIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE REPRESENTEDWITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED USERS ARE FULLY RESPONSIBLE FOR THEIR APPLICATION OF ANY PRODUCTS THE SOFTWARE LICENSE ANDLIMITED WARRANTY FOR THE ACCOMPANYING PRODUCTARE SETFORTH IN INFORMATION THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN...

Page 3: ... Connecting Two Voyager M3i USB Analyzers via the CATC Sync Expansion Card ACC EXP 002 X 7 Connecting an Advisor T3 and a Sierra M6 2 8 Connecting an Advisor T3 a Voyager M3i and a Summit T3 16 9 Connecting a SierraFC M8 4 and a Summit T3 16 via the CATC Sync Expansion Card ACC EXP 002 X 10 Connecting Three Analyzers with Built in Micro D Sync Ports 11 Connecting Three Analyzers with DB 9 Sync Por...

Page 4: ...Sync User Manual Trace File Tab 18 Time Tune Tab 19 General Tab 19 Dockable Bar 20 System Tray 20 Main Buttons 21 Session Configuration 23 Topology View 24 CrossSync Synchronized Time Stamps 25 Appendix A How to Contact LeCroy 27 Index 29 ...

Page 5: ...zation and manage the recording process Captured traffic is displayed using the latest analyzer software in separate windows with all the protocol specific search and reporting features Captured packets are displayed in separate windows that share a common time scale Navigating the traffic in either direction will scroll to the same timestamp in a synchronized window When using the CrossSync optio...

Page 6: ...rotocol Suite installers The solution includes a lightweight software control panel that starts and stops recording across daisy chained analyzers Users can sync or un sync traces on the fly The Time Tune feature provides an interactive slider for adjusting the off set between displays This makes it easy to see latency across busses Note If the system prompts you that it cannot write a trace file ...

Page 7: ...ACC EXP 002 X Up to eight analyzers may be connected in a single chain The AdvisorT3 and Sierra M6 1 use the built in Micro D Sync port and only require the Micro D Sync cable AC031XXA X Systems with an expansion slot such as Sierra M6 4 Sierra M6 2 SierraFC M8 4 Voyager M3i and Summit T3 16 require the CATC Sync Expansion Card and DB 9 Sync cable ACC EXP 002 X The Kibra 380 DDR3 and PCIe Summit T...

Page 8: ...equiring Micro D Sync cable AC031XXA X USB Advisor T3 SAS SATA Sierra M6 1 Analyzers requiring CATC Sync Expansion Cards and DB 9 Sync cable ACC EXP 002 X SierraFC M8 4 SAS SATA Sierra M6 4 SAS SATA Sierra M6 2 PCIe Summit T3 16 PCIe Summit T3 8 USB Voyager M3i Analyzers with built in DB 9 Sync ports requiring DB 9 sync cable ACC EXP 002 X Kibra 380 DDR3 PCIe Summit T28 Required Cables DB 9 Sync c...

Page 9: ...al 5 CrossSync Hardware Requirements LeCroy Corporation Micro D Sync cable AC031XXA X Micro D to DB 9 Sync cable AC030XXA X TABLE 2 2 LeCroy Analyzers and Cables Required for CrossSync Option Analyzers and Cables Product ...

Page 10: ...onized analyzers for time synchronized recording sessions CrossSync Cabling for Various Configurations Connecting a Sierra M6 1 SAS SATA Analyzer and a Advisor T3 USB Analyzer via the Micro D Sync Cable The devices are connected using their built in Sync ports Perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit ...

Page 11: ...EXP 002 X Note Refer to relevant protocol analyzer user manual for instructions on how to install the expansion board To do so perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the female end of the sync cable to the SYNC OUT port of the first analyzer 3 Connect the male end of the sync...

Page 12: ...ps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the Micro D end of the sync cable to the Sync Data port of the Advisor T3 3 Connect the male end of the DB 9 cable to the SYNC IN port of the Sierra M6 2 Alternatively connect the female end of the DB 9 cable to the SYNC OUT port of the Sierra M6 2 Figure 2 3 Co...

Page 13: ...Summit T3 16 analyzer To do so perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the Micro D end of the sync cable to the Sync Data port of the Advisor T3 3 Connect the male end of the DB 9 cable to the SYNC IN port of the Voyager M3i 4 Connect the female end of the DB 9 cable to the SY...

Page 14: ...ACC EXP 002 X Note Refer to relevant protocol analyzer user manual for instructions on how to install the expansion board To do so perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the female end of the sync cable to the SYNC OUT port of the SierraFC M8 4 3 Connect the male end of the s...

Page 15: ...e You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the analyzers using the built in on board Sync Data ports 3 Connect the Micro D end of the sync cable to the Sync Data port of the first analyzer 4 Connect the male end of the DB 9 cable to the female end of the second DB 9 cable 5 Connect the Micro D end of the sync cable to the Sync Data port of the second analy...

Page 16: ...nc cable 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the female end of the first sync cable to the SYNC OUT port of the first analyzer 3 Connect the male end of the first sync cable to the SYNC IN port of the second analyzer 4 Connect the female end of the second sync cable to the SYNC OUT port of the second...

Page 17: ...ation Connecting Kibra 380 DDR3 Protocol Analyzer for CrossSync with the IOTA Software Suite Kibra 380 usage with IOTA requires the Ref Clk In Trigger In and Trigger Out SMAs see Figure 2 7 Figure 2 7 Kibra Rear Panel Connections See the LeCroy IOTA Software Suite User Manual for details ...

Page 18: ...LeCroy Corporation Host PC Connections Using Various Configurations 14 CrossSync User Manual ...

Page 19: ...ssSync control panel requires the analyzers to be connected using their Sync ports This Sync port is built in to every Advisor T3 and Sierra M6 1 analyzer For owners of LeCroy s Summit T3 Voyager M3i and Sierra based analyzers the Sync port is available as an optional expansion board ACC EXP 002 X that can be installed by users in just a few minutes This allows developers to leverage analyzers alr...

Page 20: ...gs dialog is displayed The Settings dialog displays all the available Protocol Applications Suites Select the protocol applications you want to use and click OK The selected applications are launched automatically Figure 3 2 LeCroy CrossSync Settings Dialog Applications Tab The Applications tab displays all the available applications On subsequent sessions your preferred applications are automatic...

Page 21: ... Sequence tab is only used when using the LeCroy IOTA Software Suite It displays all the applications that are running The IOTA start capture is not hardware synced with other analyzers If other analyzers will be the trigger source then move IOTA to the top of the list If IOTA will be the trigger source then move IOTA to the bottom of the list You can move IOTA up and down as follows 1 Select IOTA...

Page 22: ... Check the box if you want to save each run in a new folder New folders are assigned names based on the recording session start date and time Figure 3 4 Trace File Tab Note The default trace file location on Windows XP is C Program Files Common Files LeCroy Shared Traces The default trace file location on Windows Vista and Windows 7 is C Users Public Documents LeCroy CrossSync Traces ...

Page 23: ...he Time Tune tab displays the following Source Double click on the icon to switch the Source Target Displays the target Delta Enter a value or slide the tuner to select the offset Time Type Select a value in seconds milliseconds microseconds or nanosec onds from the drop down list Figure 3 5 Time Tune Tab General Tab The General tab allows you set the general settings Select the check box to show ...

Page 24: ...utoHide to hide the tool bar when you move the mouse cursor to the top of the screen the tool bar will re appear Figure 3 7 Dockable Bar System Tray The application automatically installs a LeCroy CrossSync Control Panel System Tray icon for easy access Figure 3 8 System Tray Icon Right click on the System Tray icon for quick access to the control panel functions The options on the menu will be di...

Page 25: ...s Select Application The Select Application icon allows you to select the application suite you would like to run This is a dual mode button clicking on the down arrow displays the following menu FC Protocol Suite PETracer SAS Protocol Suite SATA Protocol Suite USB Protocol Suite DDR Protocol Suite IOTA Protocol Suite Devices The Devices icon opens the Devices dialog This is a dual mode button cli...

Page 26: ...if more than one application is open Vertical Displays the application windows vertically Windows are displayed cascading vertically if more than one application is open Custom Layout Displays a custom application layout Multimonitor Displays the application windows across dual monitors Save Current layout Saves the current application layout display Help The Help icon opens the Help and About dia...

Page 27: ... a session 1 Open the Devices dialog and select the devices you want to use by checking the corresponding boxes in the Set column of the list Figure 3 10 Devices Dialog 2 For each selected device click the Record Setting icon to invoke the settings dialog for that device in its respective protocol application See the protocol application s User Manual for details on how to configure the settings 3...

Page 28: ...evice Device Name and Serial Number Protocol Suite Icon of the Protocol Suite of the device being used is displayed Record Setting Click to invoke the settings dialog for that device in its respective protocol application Location Location of the device local or on the network Ports Identifies ports P1 P2 P3 and P4 A icon indicates an Analyzer is connected A icon indicates the port is not being us...

Page 29: ...nding time point taking into account the Time Tune settings Figure 3 12 Synchronized Time Stamps Using the CrossSync Control Panel you can use triggering to find the same packet traveling across both busses identifying the point where a specific bus event moves over a bridge Either analyzer can be setup as the trigger master When the trigger event is detected the capture stops and the display show...

Page 30: ...LeCroy Corporation CrossSync Synchronized Time Stamps 26 CrossSync User Manual ...

Page 31: ...ical support US and Canada 1 800 909 7112 Worldwide 1 408 653 1260 Fax your questions Worldwide 1 408 727 6622 Write a letter LeCroy Protocol Solutions Group Customer Support 3385 Scott Blvd Santa Clara CA 95054 3115 USA Send e mail psgsupport lecroy com Visit LeCroy s web site http www lecroy com ...

Page 32: ...LeCroy Corporation 28 CrossSync User Manual ...

Page 33: ...th DB 9 Sync Ports 12 Two Voyager M3i USB Analyzers via the CATC Sync Expansion Card 7 contact 27 CrossSync Cabling for Various Configurations 6 CrossSync Control Panel 16 CrossSync Hardware Requirements 3 CrossSync Multi Protocol Analysis option 1 CrossSync Software Overview 15 CrossSync Synchronized Time Stamps 25 CrossSync Capable Products 2 D Devices 21 Devices Dialog 23 Devices icon 21 Dockab...

Page 34: ...ect Application icon 21 Session Configuration 23 Settings 21 Settings icon 21 support 27 System Tray 20 System Tray Icon 20 System Tray Icon Functions 20 T Technical Support 27 telephone number 27 Time Tune Tab 19 Topology View 24 Trace File Tab 18 W web site 27 Website CATC 27 ...

Page 35: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Teledyne LeCroy AC031XXA X AC030XXA X ...

Reviews: