- 16 -
ENGLISH
MAINTENANCE
Ordinary maintenance
N.B. :
The owner should execute the following operations any time it is
required:
- Clean the area around the device.
- Remove the rabble on the sliding rail.
- Clean the part of the device next to the pinion.
- Remove possible rabble from the rack.
Six-monthly execute ordinary maintenance of the device.
Any operation of ordinary maintenance is to be performed by
qualified technical staff authorized by the Manufacturer.
- Make sure about solidity and smoothness of the gate.
- Grease the gear unit.
- Lubricate the wheels of the gate.
Extraordinary maintenance
- In the case hard interventions are required on the device, it is
advisable to remove this one, in order to allow the repairs in a
workshop by technicians of the Manufacturer or authorised by it.
Capacitor connection
- In the motor BOOST 5 connect the capacitor between the black
wire (Open) and the brown wire (Close) of the electric engine.
- In the motor BOOST 10 connect the capacitor between the
black wire (Open) and the brown wire (Close) of the electric engine.
Cable of limit switches
The device is equipped with two magnetic Limit switches. From the
Limit switches block three wires come out. In the following table the
data concerning the Limit switches cable, required for the connection
to the control board, are reported.
Cable 3 x 1,5 mm
Colour
Common
Blue
Limit switch OPENING
Black/Brown
Limit switch CLOSING
Black/Brown